8
Festo — CPX-F8DE-P — 2022-10d
Safety
1.4
Rules for product configuration
Operation of the input module CPX-F8DE-P is permissible exclusively in CPX terminals.
Operation of the CPX-F8DE-P is permissible only in combination with the following PROFIsafe-compat-
ible bus nodes:
Bus node
from revision
Network protocol
CPX-FB13
1)
30
PROFIBUS
CPX-FB33
2)
21
PROFINET IO
CPX-M-FB34
2)
21
PROFINET IO
CPX-M-FB35
2)
21
PROFINET IO
CPX-FB43
2)
50
PROFINET IO
CPX-M-FB44
2)
50
PROFINET IO
CPX-M-FB45
2)
50
PROFINET IO
1)
è
Description of CPX-FB13
2)
è
Description of CPX-(M)-FB33/34/35/43/44/45
Tab. 1: Permissible PROFIsafe-compatible bus nodes
–
Use exclusively metal interlinking blocks – e.g. CPX-M-GE-EV
–
Comply with all technical data
Otherwise, malfunctions can occur.
The CPX-F8DE-P may only be operated with the following manifold blocks:
Manifold block
Sample application
CPX-M-AB-4-M12X2-5POL-T
Connection of OSSD sensors with a current consumption up to 0.7 A
–
Power supply via contacts T0, T2, T4, T6
Connection of sensors for mechanical switch contacts
–
Clock signals via contacts T0 ... T7
CPX-M-AB-4-M12X2-5POL
Connection of OSSD sensors with a current consumption up to 2 A
CPX-AB-8-KL-4POL
Connection of sensors via the terminal strip
CPX-AB-ID-P
Setting of a coded identifier using an 8x DIL switch
–
It is not possible to connect sensors
Tab. 2: Permissible manifold blocks
For more information about the supported product versions of CPX see