20
Festo — CPX-F8DE-P — 2022-10d
System overview CPX-F8DE-P
2.1.2
Components
2.1.2.1
Manifold blocks
The manifold block provides the input module with connection technology. The CPX-F8DE-P may only
be operated with the following manifold blocks:
Manifold block
description
CPX-M-AB-4-M12X2-5POL-T
M12 metal connection technology
–
4 M12 sockets with metal thread, 5-pin
–
for the use of sensors with static or clocked 24 V DC power supply
–
for the use of sensors with a current consumption up to 0.7 A
–
degree of protection IP65 when using cover caps ISK-M12 for
unused connections
CPX-M-AB-4-M12X2-5POL
M12 metal connection technology
–
4 M12 sockets with metal thread, 5-pin
–
for the use of sensors with static 24 V DC power supply only
–
for the use of electronic sensors with current consumption up
to 2 A
–
degree of protection IP65 when using cover caps ISK-M12 for
unused connections
CPX-AB-8-KL-4POL
Terminal strip connection technology
–
2 terminal strips, 16-pin (4 x 4-pin)
–
all cores can be placed individually in a spring-loaded terminal
–
Connections combined in groups of 4 with one functional earth
connection for each group
–
for the use of sensors with static or clocked 24 V DC power supply
–
for the use of sensors with mechanical switch contacts and elec-
tronic sensors with a current consumption up to 0.7 A
–
Degree of protection IP20
–
Degree of protection IP65 with use of covering AK-8KL
CPX-AB-ID-P
Manifold block without connection technology
–
coded identifier
Tab. 9: Permissible manifold blocks