Festo — CPX-F8DE-P — 2022-10d
System overview CPX-F8DE-P
23
Interlinking block
description
CPX-M-GE-EV-Z-PP-5POL
with additional supply, connection: push-pull (5-pin)
CPX-M-GE-EV-W-M12-5POL
with forwarding supply, connection: M12 (5-pin)
Tab. 11: Permissible interlinking blocks
2.1.3
Supported CPX product versions
A PROFIBUS or PROFINET-compatible bus node is required for control of the input module CPX-F8DE-P.
The CPX terminal must be fitted with one of the following bus nodes
è
Product labelling.
Bus node
From revision
Network protocol
CPX-FB13
30
PROFIBUS
CPX-FB33
21
PROFINET IO
CPX-M-FB34
21
PROFINET IO
CPX-M-FB35
21
PROFINET IO
CPX-FB43
50
PROFINET IO
CPX-M-FB44
50
PROFINET IO
CPX-M-FB45
50
PROFINET IO
Tab. 12: Bus node for control of the CPX-F8DE-P
The following product versions of the CPX terminal support operation of the input module CPX-F8DE-P
in connection with the listed bus nodes:
Product version
description
Electrical terminal
Modular electrical terminal CPX (without pneumatic modules)
MPA-S-FB-VI
Valve terminal MPA-S with modular electrical peripheral equipment CPX