8
Commissioning
NOTICE!
Malfunction due to switching on the higher-order controller and automation system CPX-AP in the
incorrect order.
•
Switch on the higher-order controller and automation system CPX-AP according to the preset
order of the network used.
1. Using the appropriate software, set up an automation project for the higher-order controller.
2. Import the device description file into the software
è
3. Configure the automation system CPX-AP in the software:
–
System structure
–
Network addressing
–
Address assignment of modules
è
Instruction manual for automation system CPX-AP
4. Transfer the automation project to the higher-order controller.
Behaviour of the display components of the module after error-free commissioning
[MD]
[SD]
[PL]
[MT]
green on
green on
green on
off
Tab. 10 Behaviour of the display components after error-free commissioning
[TP1], [TP2]
[NS]
[MS]
flashing green
green on
green on
Tab. 11 Behaviour of the display components after error-free commissioning
Information on troubleshooting in the event of incorrect behaviour:
è
Instruction manual for automation system CPX-AP
è
10 Diagnostics and fault clearance
9
Parameterisation
Various parameters are available for reading out information about the modules in an automation sys-
tem CPX-AP and adapting the modules to the application situation.
Parameterisation can be conducted via web browser, L5X file or parameter object.
Commissioning
12
Festo — CPX-AP-I-EP-M12 — 2019-08