MES Operation
Interactive messages are displayed via a pop-up window at HMI
The Pop Up has four buttons.
Example application module output - interactive error message in default mode
Position
Note
1
Repeat - An attempt is made to run the application again with the same parameters.
2
Ignore
–
The application is not executed, but is treated in the MES as if the order step had been executed without
errors.
3
Abort
–
The application is no longer executed. In the MES, this order position is terminated with an error and
canceled, depending on whether an error step has been defined or not.
4
Reject order - the application will not be executed. In the MES, the step of this order position is reset and restarted
the next time the workpiece carrier arrives.
9.2.3
General
Value
Text
Fix error
100
Order aborted with errors!
Start order again
9.2.4
Application module labeling
Value
Text
Fix error
1060
Suction plate is occupied!
Please remove label and check sensor BP6.
1061
Label was not placed!
Check suction plate and sensor BP6.
1062
Printer not ready
Switch on / check printer
1063
Printing label failed.
Check printer
1064
Build up vacuum failed
Check vacuum unit
5067
No workpiece on pallet detected!
Check pallet / sensor BG1.
Содержание CP Factory
Страница 1: ...Festo Didactic 8152450 en 10 2022 8152450 Labeling CP Factory CP Lab Original operating instructions...
Страница 21: ...Fundamental safety instructions Festo Didactic 8065842 en 21 4 11 CE Declaration of Conformity...
Страница 22: ...Fundamental safety instructions 22 Festo Didactic 8065842 en...
Страница 23: ...Fundamental safety instructions Festo Didactic 8065842 en 23...
Страница 27: ...Technical data Festo Didactic 8065842 en 27 Illustration similar...
Страница 67: ...Operation Festo Didactic 8065842 en 67 2 Then click on Setup setup mode is active 3 Change to Setup mode page...
Страница 68: ...Operation 68 Festo Didactic 8065842 en 4 Choose application...