Fundamental safety instructions
14
© Festo Didactic
8065842 en
4.4
Pneumatic components
WARNING
•
Depressurize the system!
–
Switch off the compressed air supply before working on the circuit.
–
Check the system using pressure gauges to make sure that the entire circuit is
fully depressurized.
–
Please note that energy may be stored in reservoirs. Further information on this
issue is available in the datasheets and operating instructions included with the
components.
•
Risk of injury when switching on compressed air!
Cylinders may advance and retract automatically.
•
Risk of accident due to advancing cylinders!
–
Always position pneumatic cylinders so that the piston rod’s working space is
unobstructed along its entire stroke range.
–
Make sure that the piston rod cannot collide with any of the rigid components in
the setup.
•
Risk of accident due to pneumatic tubing slipping off!
–
Use shortest barbed tubing connectors possible.
–
If pneumatic tubing slips off, switch off the compressed air supply immediately.
•
Do not exceed the maximum permissible pressure of 600 kPa (6 bar).
•
Do not switch on the compressed air until all the barbed tubing connectors have
been connected and secured.
•
Do not disconnect pneumatic tubing while it is under pressure.
–
Do not attempt to seal or plug pneumatic tubing or plug connectors with your
hands or fingers.
•
Check the condition of the condensate in the service unit regularly. If necessary,
drain the condensate and dispose of it properly.
Содержание CP Factory
Страница 1: ...Festo Didactic 8152450 en 10 2022 8152450 Labeling CP Factory CP Lab Original operating instructions...
Страница 21: ...Fundamental safety instructions Festo Didactic 8065842 en 21 4 11 CE Declaration of Conformity...
Страница 22: ...Fundamental safety instructions 22 Festo Didactic 8065842 en...
Страница 23: ...Fundamental safety instructions Festo Didactic 8065842 en 23...
Страница 27: ...Technical data Festo Didactic 8065842 en 27 Illustration similar...
Страница 67: ...Operation Festo Didactic 8065842 en 67 2 Then click on Setup setup mode is active 3 Change to Setup mode page...
Страница 68: ...Operation 68 Festo Didactic 8065842 en 4 Choose application...