CP-AM-LABEL
6
Z-Axis is between
T32-T_ZIsBetween
Wait for Z-Axis not in upper and not in lower position, wait for not BG3
and not BG4
S28-S_ResZBetween
Reset: Ventilate cylinder chambers of raising and lowering Z-axis, set
MB3, set MB4
T34-T_WaitBetween
Wait until chambers are filled, wait 300ms
S24
Jump back to step 24