General safety instructions
–
Also always observe the general safety regulations for the motor controller CMMP-AS-...-M0.
The general safety regulations for the CMMP-AS-...-M0 can be found in the hardware documentation
GDCP-CMMP-M0-HW-....
Tab. 2 Documentation for the motor controller CMMP-AS-...-M0.
NOTICE
Loss of the safety function!
The safety functions might fail if you do not comply with the parameters required for the surroundings
and connections.
• Observe the specified environmental and connection conditions, in particular the input voltage
tolerances
NOTICE
Damage to the motor controller due to incorrect handling.
Incorrect handling may cause damage.
• Switch off the power supply before mounting and installation work. Do not switch on the supply
voltages until mounting and installation work is completely finished.
• Observe the handling specifications for electrostatically sensitive devices.
2.1.2
Intended use
The motor controller CMMP-AS-...-M0 supports the following safety function:
–
Safe Torque Off (STO) with SIL 3 in accordance with EN 61800-5-2/EN 62061/IEC 61508 and/or
category 4/PL e in accordance with EN ISO 13849-1.
The motor controller CMMP-AS-...-M0 is intended for installation in machines or automation systems
and to be used as follows:
–
in excellent technical condition,
–
in its original condition, without unauthorised modifications,
–
within the limits of the product defined by the technical data
–
in an industrial environment.
NOTICE
In the event of damage caused by unauthorised manipulation or use other than the intended use, the
guarantee will be invalidated and the manufacturer will not be liable for damages.
2.1.3
Achievable safety level, safety function in accordance with EN ISO 13849-1/EN 61800-5-2
The motor controller CMMP-AS-...-M0 with integrated STO safety function fulfils the requirements for
–
Category 4/PL e in accordance with EN ISO 13849-1,
–
SIL CL 3 in accordance with EN 62061,
and can be used in applications up to cat. 4/PL e in accordance with EN ISO 13849-1 and SIL 3 in
accordance with EN 61800-5-2/EN 62061/IEC 61508.
The achievable safety level depends on the other components used to implement a safety function.