Assembly and installation
Plugs
Pin
Designation
Value
Description
8
0V
0 V
Reference potential for auxiliary supply voltage.
7
24V
+24 V DC
Auxiliary supply voltage (from the 24 V DC logic
supply of the motor controller).
6
C2
–
Feedback contact for the “STO” status on an
external controller.
5
C1
4
0V-B
0 V
Reference potential for STO-B.
3
STO-B
0 V / 24 V
Control input B for the STO function.
2
0V-A
0 V
Reference potential for STO-A.
1
STO-A
0 V / 24 V
Control input A for the STO function.
Tab. 9: Pin allocation [X40] (diagram of the plug on the device)
The STO-A and STO-B control inputs must be connected in parallel over two channels to ensure the
STO “Safe Torque Off” function
For example, this interface can be part of an emergency stop circuit or a safety door installation.
4.2.3
Minimum wiring for initial start-up [X40]
For initial commissioning of the motor controller without safety engineering, the motor controller
CMMP-AS-…-M0 can be wired with a minimum circuit in accordance with
Fig. 6 with an emergency
NOTICE
Safety functions must never be bypassed.
Install the minimum circuits for the STO-A/STO-B and 0V-A/0V-B inputs for initial commissioning in
such a way that they must be removed when the final safety circuitry is installed.