36
Festo — CMMP-AS-...-M0 — 2022-07c
Technical appendix
Safety engineering
T
[years]
20
Proof test interval
Service life in accordance with EN ISO 13849-1
MTTF
d
[years]
1370
Mean time to dangerous failure.
Safety specifications
Well-tried component
Yes, for the STO safety function
Tab. 16: Safety engineering
8.1.2
General, operating and environmental conditions CMMP-AS-...-M0
The complete technical data for the CMMP-AS-...-M0 can be found in the hardware documentation
GDCP-CMMP-M0-HW-...
General technical data
Approvals
Certificates, declaration of con-
formity
The device is intended for use in an industrial environment. Measures for interference suppression
may be required in residential areas.
Tab. 17: General technical data
Operating and environmental conditions for CMMP-AS-...-M0
Permissible setup altitude above mean sea level
–
at nominal power
[m]
1000
–
with power reduc-
tion
[m]
1000 … 2000
Humidity
[%]
0 … 90 (non-condensing)
Degree of protection
IP20
Pollution degree in
accordance with EN
61800-5-1
2
The integrated safety-engineering equipment requires compli-
ance with pollution degree 2 and thus a protected installation
space (IP54). It must always be ensured by taking appropriate
measures, e.g. by installation in a control cabinet.
Operating temperature [°C]
0 … +40
Operating temperature
with power reduction
2.5% per K
[°C]
+40 … +50
Storage temperature
[°C]
-25 … +70