3
Mounting and installation
24
Festo – GDCP-CAMC-G-S1-EN – 1412b – English
3
Mounting and installation
3.1
Mounting/Dismounting
The safety module CAMC-G-S1 is suitable only for integration into the motor controller CMMP-AS-…-M3.
It cannot be operated outside the motor controller.
Warning
Danger of electric shock if the safety module is not mounted.
Contact with conducting parts will cause severe injuries and may result in death.
Before touching conducting parts during maintenance, repair and cleaning work and
during long service interruptions:
1. Switch off the power to the electrical equipment and secure it to prevent a restart.
2. After switching it off, wait at least 5 minutes of discharge time and check that it is
voltage-free before accessing the controller.
Note
Incorrect handling can damage the safety module or controller.
Before mounting and installation work, switch off the supply voltage. Switch on the
supply voltage only when the mounting and installation work have been completely
finished.
Never unplug a module from, or plug a module into the motor controller when it is
energised!
Observe the handling specifications for electrostatically sensitive devices. Do not
touch the components or the conductive tracks of the printed circuit board nor the
pins of the manifold rail in the motor controller. Hold the safety module only by the
front plate or the edge of the board.
Mounting safety module
1. Slide safety module into the guides.
2. Tighten screws. Observe tightening torque 0.4 Nm ± 20 %.
Result: Front plate has conducting contact with the housing.
Dismantling safety module
1. Unscrew screws.
2. Loosen the safety module by gently levering the front cover
or by pulling on the counter-plug by a few millimetres and
pull it out of the slot.
Fig. 3.1
Mounting/Dismounting