GENERAL SPECIFICATIONS
General specifications
European Directives
• This manual and the wiring diagram supplied with the unit must be kept in a dry place and ready to hand for future consultation
when required.
• This manual has been compiled to ensure that the unit is installed in the correct way and to supply comprehensive information
about how to correctly use and service the appliance.
Before proceeding with the installation phase, please carefully read all the
information in this manual, which describes the procedures required to correctly install and use the unit.
• Strictly comply with the instructions in this manual and conform to the current safety standards.
• The appliance must be installed in accordance with the laws in force in the country in which the unit is installed.
• Unauthorized tampering with the electrical and mechanical equipment will
VOID THE wARRANTY.
• Check the electrical specifications on the identification plate before making the electrical connections. Read the instructions in the
specific section where the electrical connections are described.
• If the unit must be repaired for any reason, this must only be done by a specialized assistance center recognized by the manufacturer
and using geuine spare parts.
• The manufacturer also declines all liability for any damage to persons or property deriving from failure of the information in this
manual to correspond to the actual machine in your possession.
• Proper uses: this series of chillers is designed to produce cold or hot water for use in hydronic systems for conditioning/
heating purposes. The units are not suitable for the production of domestic hot water.
Any use differing from this proper use or beyond the operating limits indicated in this manual is forbidden unless
previously agreed with the manufacturer.
• The prevention of the risk of fire at the installation site is the responsiblity of the end user.
The company hereby declares that the machine in question complies with the matters prescribed by the following Directives:
•
Machine Directive
2006/42/CE
•
Directive governing pressurized vessels (PED)
97/23/CE
•
Electromagnetic compatibility Directive
(EMC)
2004/108/CE
•
Low voltage Directive (LVD)
2006/95/CE
Any other Directives have to be considered not applicable.
Identification plate of the Unit
The figure on the left depicts the identification plate of the unit, affixed to the outer left-hand side of
the Electric Panel.
A description of the data is given below:
Standard versions
A -
Trademark
B -
Model
B1-
Code
C -
Serial number
D -
Cooling Capacity
E -
Heating Capacity
F -
Power input in COOLING mode
G -
Power input in HEATING mode
H -
Reference standard
I -
Electric power supply
L -
Maximum load current
M -
Type of refrigerant and charge
N -
Shipping weight of the unit
O -
Sound pressure level at 1m
P -
IP Level Protection
Q -
Maximum pressure - High Side
R -
Maximum pressure - Low Side
S -
PED certification authority
Special versions
A -
Trademark
B -
Model
B1-
Code
C -
Serial number
D -
Cooling Capacity (same as Standard Version of the unit)
E -
Heating Capacity
for IR unit, VD version, Recovered Heating Capacity
for IP unit, VD version, Heating Capacity / Recovered Heating Capacity
F -
Power input in COOLING mode (same as Standard version of the unit)
G -
Power input in HEATING mode
H -
Reference standard
I -
Electric power supply
L -
Maximum load current
M -
Type of refrigerant and charge
N -
Shipping weight of the unit
O -
Sound pressure level at 1m
P -
IP Level Protection
Q -
Maximum pressure - High Side
R -
Maximum pressure - Low Side
S -
PED certification authority
NOTE: The identification plate of the Brine Unit (BR - BP) is filled out as