5
GENERAL SPECIFICATIONS
TECHNICAL DATA
In cooling mode: ambient air temperature 27°CDB, outdoor temperature 19°CWB 35°CDB
In heating mode: ambient air temperature 20°CDB, outdoor temperature 7°CDB - 6°CWB
*: For units 9-12-18-22, data referring to Mono-split connection, for unit 7 nominal data referring to Multi Split unit connection . In case of
Multi Split connection, the value depends on the combination of the active units
**: Sound pressure level detected at a distance of 1 meter, in a 100m
3
environment with reverberation time of 0 .5 seconds .
MODEL
9
12
18
22
U .M
Power supply
230-1-50
V-f-Hz
Cooling capacity *
Rated
2600
3500
5270
6450
W
Heating capacity *
Rated
2800
3650
5500
6600
W
Indoor unit air flow rate
S .Max
530
660
850
1150
m³/h
Max
490
540
720
1050
m³/h
Med
430
460
610
950
m³/h
Min
330
330
520
850
m³/h
Indoor unit sound pressure
level**
S Max
39
42
46
48
dB(A)
Max
36
39
42
45
dB(A)
Med
32
33
39
42
dB(A)
Min
26
26
36
39
dB(A)
Connections LIQUID line
1/4
1/4
1/4
1/4
“
Connections GAS line
3/8
3/8
1/2
5/8
“
Indoor unit net weight
9 .5
10 .5
14
16 .5
Kg
Indoor unit packaging
dimensions
L
871
930
1047
1158
mm
H
290
279
314
352
mm
D
352
352
377
413
mm