background image

INSTALLATION AND USER MANUAL

E N G L I S H

BASIC SMILE VDS MONITOR

Содержание SMILE 3.5" Monitor

Страница 1: ...INSTALLATION AND USER MANUAL E N G L I S H BASIC SMILE VDS MONITOR...

Страница 2: ...ax electronics develops and manufactures renown systems that meet the highest design and technology standards Your FERMAX video door entry system will allow you to communicate with the entry panel see...

Страница 3: ...Monitor 16 Programming Administrator Menu 17 Access the Administrator menu 17 a Code options 18 b Configuring conversation mode 24 c Images 25 d Date and Time 25 e Functions 25 f Parameters 37 g Reset...

Страница 4: ...nmm SMILE 3 5 Monitor 196 4 5 209 SMILE 7 Monitor Fermax built in 3 5 monitor ref 6546 Height x Width x Depth 186 x 116 x 46 mm Fermax built in 7 monitor ref 6551 Height x Width x Depth 186 x 198 x 46...

Страница 5: ...Page 5 SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS INSTALLING THE BUILT IN MONITOR 2 1 3 5 3 1 6 0 m 5 2 5 f e e t 4 5 SMILE 3 5 Monitor...

Страница 6: ...Page 6 SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS 2 1 7 3 4 5 1 6 0 m 5 2 5 f e e t SMILE 7 Monitor...

Страница 7: ...LE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS INSTALLINGTHESURFACEMONITOR 1 3 2 4 3 5 1 60m 5 25 feet SMILE 3 5 Monitor SMILE 7 Monitor 1 60m 5 25 fe...

Страница 8: ...rogramming chapter T call button connection for residential door P1 A call extension connection ref 2040 light and bell activator ref 2438 etc Video terminals V live M mesh CT camera Activation 12 Vdc...

Страница 9: ...R VIDEO 2 SALIDAS V 5 V 1 M 18 75 M R1 3 4 V 2 REF 2448 6 V M M L R F2 T A L F1 CT V M M V M V AUX F2 T A L F1 CT V M M V 75 Ohm M V AUX COAX F2 T A L F1 CT V M M V M V AUX 75 Ohm L M V 2 OUTPUTS VIDE...

Страница 10: ...t It has capacitive buttons Open door Call to guard Call Volume Regulation Call disconnection Do not Disturb Ringtone Selection 5 options Doorbell Programming via the terminal and via the entry panel...

Страница 11: ...he monitor s default internal timer is 90 seconds Notes The conversation is private no other terminal can hear it Handsfree mode is the default mode While the audio channel is open the input audio can...

Страница 12: ...channel is busy an error tone BEEP will be generated and auto start will not activate nor will the call to the guard The auto start function is always used on the main panel except where a call is re...

Страница 13: ...lock release is activated This output remains active while pressing the button See chapter e5 Auxiliary unction F2 Button Menu Adjustments and configuration In order to access the Administrator menu f...

Страница 14: ...screen navigation buttons and are managed with the corresponding capacitive buttons located on the monitor capacitive buttons Navigation buttons Return to the previous screen or stand by Select the p...

Страница 15: ...mera this shows a panel icon in the upper left corner of the monitor Enter the calling code for this monitor from the panel Depending on the type of panel installed pressing the corresponding button o...

Страница 16: ...appears 3 This option programmed by the VDS monitor is selected as default The selected option is displayed on the white line under the icon The first thing the monitor then does is indicate the numbe...

Страница 17: ...Note Upon exiting programming the wildcard button stops blinking indicating that the monitor is programmed 0 2 8 _ _ _ 2222 4444 0 2 8 PROGRAMMING ADMINISTRATORMenu Access the Administrator menu When...

Страница 18: ...to the next digit and replaces the previous one with It restarts with the first digit Notes After entering 3 continuous erroneous codes the monitor will be blocked for 5 minutes RESET the Administrat...

Страница 19: ...ng forwarded to displays an icon on the screen indicating that the call is a forwarded call a 3 Programming a call forward Option 1 from the Monitor 1 Select the programming option from the monitor VD...

Страница 20: ...ect programming from the panel select the panel from the VDS 2 line with the right arrow 0 2 8 _ _ _ 2222 4444 2 The selected option is displayed with the white line under the icon Press and a screen...

Страница 21: ...mage and after a few seconds the monitor returns to the programming screen Panel icon 0 2 8 0 7 1 2222 4444 1 4 Exit Programming When you press you exit to the previous programming menu Continue press...

Страница 22: ...tion is confirmed since the white line stops blinking and remains constant 4 Press to exit to the previous menu Continue pressing until you reach the desired menu or you exit programming Select call f...

Страница 23: ...te point on the screen next to the call forward icon In order to remove the selection re press When a call is made to the monitor with call forward activated on the monitor being called an icon appear...

Страница 24: ...ted with the cursor This moves to the next digit and replaces the previous one with It restarts with the first digit 0 0 0 0 1 8 1 8 0 2 8 _ _ _ 2222 1818 b Configuring conversation mode Within the co...

Страница 25: ...rs white line under the cursor press if you want to remove the selection you also press Press to exit to the previous menu and confirm the selected options Continue pressing until you reach the desire...

Страница 26: ...the wildcard button wildcard If we exit without changing anything we lose the auto start function on this button since in normal mode we can not assign the same function as a shortcut button and a wil...

Страница 27: ...tion Activation is confirmed since the white line stops blinking and remains constant 6 Press to exit to the previous menu Continue pressing until you reach the desired menu or you exit programming M...

Страница 28: ...n shows the non timed default option and the user can confirm or change the value to the desired hours and minutes _ _ _ _ 2 Enter the hours and minutes you want to activate the do not disturb functio...

Страница 29: ...rt the process form the 1st point _ _ _ _ 5 If you want to select this mode indefinitely upon entering in this screen the first number is blinking press until you view the cursor press the remaining d...

Страница 30: ...Calling a guard unit In installations with a Guard unit we can make a call to this via the lock release button default configuration when the monitor is in standby When we make a call and it is confi...

Страница 31: ...guard The auto start function is always used on the main panel except where a call is re ceived on the secondary panel Once the conversation is over auto start will activate on the secondary panel fo...

Страница 32: ...function F1 The function F1 and F1 terminal have the option of being configured You can select between Sending a negative output and Panic call to the MDS Guard Unit input It is initially configured...

Страница 33: ...n the corresponding command is sent through the bus You must first activate the Panic Alarm function as follows o Wildcard button in this mode it lights up red or o By pressing the shortcut button or...

Страница 34: ...e screen notifies of the action F2 OK The function is enabled as a shortcut button and also appears in the menu via the menu shortcut buttons This output remains active while pressing the button The F...

Страница 35: ...shortcut button x This function is enabled as a shortcut button and also appears in the menu x x x M x M x Via the MENU Pressing Menu for 3 seconds With Shortcut buttons Short press Menu CCTV When the...

Страница 36: ...een permanently remaining on when a call is made from the panel Via the MENU Pressing Menu for 3 seconds For Shortcut buttons Short press Menu For example Lift Control as a shortcut buttons x This fun...

Страница 37: ...forward Option 2 from Panel Monitor Enable Call forward Select Call forward f Parameters The installer may enable determined parameters that are not enabled by default 1 Once the installer accesses th...

Страница 38: ...tion is activated displaying the call origin on the monitor s screen 1 panel icon indicating the panel number f3 Induction ear loop This function is available on depending model f4 Auxiliary video wit...

Страница 39: ...anel f5 Activate auxiliary devices The following may be configured call extension light and ringtone activator etc for this to be enabled even if the do not disturb mode is selected when the monitor r...

Страница 40: ...ve buttons indicating that the reset is being performed 2 When all capacitive buttons have been lit this option is saved g3 Factory Configuration This leaves the monitor with the default configuration...

Страница 41: ...is not programmed ADJUSTMENTS Video and Audio Video adjustments Brightness Contrast Colour The monitor allows you to adjust brightness contrast and colour while you have received a call or performed...

Страница 42: ...LE VDS SMILE VDS SMILE VDS SMILE VDS contrast brightness colour 1 1 1 2 Select the desired option and increase or decrease the video adjustments according to the selected option Button to decrease But...

Страница 43: ...st the audio adjustments audio 1 Select the audio adjustments option with the corresponding capacitive button 1 1 Capacitive button to decrease audio Capacitive button to increase audio 2 While in aud...

Страница 44: ...hite line under the icon Press and a screen appears to access the User menu to access the screen CONFIGURATION menu The icons viewed on the screen navigation buttons and are managed with the correspon...

Страница 45: ...2 or door bell For example panel 1 white line under the icon Press you access the ringtone 2 Within the ringtone white line under the icon if you press you change and listen to the different ringtone...

Страница 46: ...s continuos mode is selected the ringtone is placed 3 times Audio Adjustments To regulate the volume 1 Select the audio adjustments option via the cursors white line under the icon and press The follo...

Страница 47: ...ing the ringtone When we select this function for the first time the screen shows the non timed default option and the user can confirm or change the value to the desired hours and minutes For more de...

Страница 48: ...aller Via the MENU Pressing Menu for 3 seconds The same operation can also be performed via the menu s icon If you want to select this mode indefinitely upon entering in this screen the first number i...

Страница 49: ...The monitor s default internal timer is 90 seconds Notes The conversation is private no other terminal can hear it Handsfree mode is the default mode While the audio channel is open the input audio c...

Страница 50: ...n panel except where a call is received on the secondary panel Once the conversation is over auto start will activate on the secondary panel for 30 seconds After this time it will activate on the main...

Страница 51: ...The option of activating an output terminal F2 once the lock release is activated This output remains active while pressing the button Notice Function assigned by the installer Consult the installer...

Страница 52: ...tically go off after 30 seconds While in simplex conversation mode press the button to speak and release to listen When the call button on the Entry Panel is pressed a call tone is produced both on th...

Страница 53: ...on for 2 seconds To activate the audio and speak to the visitor or open the door follow the steps above Ifcommunicationisnotestablishedwiththeentrypanel the monitor will automatically switch off after...

Страница 54: ...VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS Opening the Door When a call is received from the entry panel you can open the door at any time by pressin...

Страница 55: ...Page 55 SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS SMILE VDS...

Отзывы: