Parameter configuration in BUS2 Digital panels
The Digital BUS2 panels have added functions, which are programmed using the keypad and display:
- Electronic directory:
Enables the introduction of details for up to 350 users (residents) (although up to a maximum of 199
apartments). This way, various users can be registered for the same apartment.
This function enables visitors to see the details of residents registered in the directory, thus simplifying the
search process (via arrows) and call procedure (once the person has been found) by simply pressing the key
.
- Personalised opening codes:
This enables every user to be allocated a personalised code, proximity care or key button (the last two options are
only available if a secondary proximity reader ref. 23352 or key button ref. 23362 is available) in order to access the
site.
- 4-digit call codes:
The digital directory can also be used to establish 4-digit call codes (0001....9999), thus enabling the creation of
2-2 combinations (two digits for the floor and two for the apartment). This prevents the restriction of
combinations to the BUS2 range (from 1 to 199).
- Programming and configuring door lock-release times.
Programming user data
1.- Enter programming......................................................................................
2.- User menu................................................................................................................
3.- Add users..................................................................................................................
Programming the door lock-release code on Digital BUS2 panels
1.- Enter programming....................................................................................................
2.- Programming door lock-release times menu..................................................................
3.- Door opening times from apartment (tO).......................................................................
This is the door lock-release activation time when the door opening command is activated from the
apartment terminal: telephone or monitor. A value between 1 and 99 seconds must be programmed.
This is validated by pressing the ‘B’ key.
4.-Door opening times from panel...............................................................................
This parameter defines the time for which the door lock-release will be active once the door opening
button connected to the panel is pressed, or when a valid user code is entered: on the key pad, or
using the key button or proximity card. A value between 1 and 99 seconds must be programmed.
This is validated by pressing the ‘B’ key.
5.-Disconnect and reconnect power supply.
*Name
: 16 characters. This is displayed on the first line in the display. If ‘*’ is introduced, this
information will not be displayed.
*Line 2
: 16 characters. This is displayed on the second line of the display and can be used to
register more than one user per apartment or to indicate the type of business.
*Line 2?
: press ‘A’ to allow the information introduced in the corresponding field to appear on Line 2.
Press ‘B’ to display the call code only (‘DOOR: xxxx’).
* Call code
: code from 0001 to 999 which must be entered by the visitor in order to call this user.
This CANNOT be repeated. Press ‘A’ to correct. Validate by pressing ‘B’.
* Telephone code
:
line number
to which a call is made when the
call code
is entered or when a
search is carried out on the screen and %’ is pressed. Like the rest of the BUS2 system, the line
number must be a value between 001 and 199 and it must have been programmed previously in the
telephone/monitor. Press ‘A’ to correct. Validate by pressing ‘B’.
* Opening code
: if using the keypad, the 6 digits must be introduced. If fewer are used, the first 4 or
5 digits should be used, leaving out the numbers on the right. Press ‘A’ to correct. To validate, press
‘B’.
Below, a quick guide to programming the basic BUS2 Digital panel parameters is shown (for more information concerning
programming, see ‘Manual Administrator BUS2 Panels with Keypad’).
AB21AB 24797
+
+
0
M 1 2 3 4
p Us Pa Ut Ti
1
U 1 2 3 4 5 6 7
s + - M T R C O
1
AB21AB 24797
+
+
0
M 1 2 3 4
p Us Pa Ut Ti
4
B
B
Name
María Pons
Line 2
Dentist
Line 2?
(A=Yes)
Call code
0012
Telephone code
012
Door opening code
123456
Door opening code
123456 N0001
Time A (1-99)
04
Time B (1-99)
04