IP VarioBell
- installation and operating instructions
46
control of mechanical bell. During button press is relay activated in
monostable mode for closing time. If in the phonebook filled for this
button telephone number then be combined with relay closing with
calling telephone number.
RC command at relay ON
– Enable setup command sends to external device
(for example WEB relay) during relay closing. Command is sending by
protokol HTTP (GET request). The command must be in format
http://ip_address/command
.
Specific
command,
refer
to
the
manufacturer's documentation WEB relay.
RC command at relay OFF-
Enable setup command sends to external device
(for example WEB relay) during relay opening. Command is sending
by protocol HTTP (GET request). The command must be in format
http://ip_address/command
.
Specific
command,
refer
to
the
manufacturer's documentation WEB relay.
Codes for relay control
– here is 10 basic central codes for relay. Moreover
every subscriber in phone book has his own priváte cod efor relay
control ( code keylock from buttons). Those 10 codes might be
assigned as codes from buttons (code keylock) or by phone (DTMF).
Further is possible assign feature relay closing/opening (ON/OFF). The
Code validity is discriminated by time according selected time plan.
Examples:
1. Closing switch 1 from the phone (DTMF)
– on the picture is filled with code 55
without any time limit, closing the switch is activated by dialing 55 from phone
2. Closing switch 1 from buttons
– on the picture is filled with code 11221 with
time limitation (open time), closing the switch is activated by pressing a
sequence of buttons 11221 on IP Fermax