44
function. When such status repeats regularly (for example school) you
can use time plan.
Time table
– defines time period when relay is working and hen not. For example
is shop operation time , school, etc..
Relay mode -
monostable
– by code is closed and after preprogrammed timeout is
open. Using for electrical lock switching, sliding gates control, button
press signalling etc... (
for control codes setting you must insert „ON” (via
follow)
bistable
– by code is closed and stay closed till moment of open by other
code.
For this purpose is beside control codes posibility select „ON” for
closing a
nd „OFF” for open. (via follow)
Delay time
– is time, between closing code evaluation and relay closing. It has
no influence for open code which is performed immediately. Closing
time is calculated from real relay closing. Using is for example:
progressive door opening, we setup same closing code for both relays,
by this delay is monitored walking time from first to second doors.
This
feature is adjustable by synchronization as well. By synchronization
delay are available individual codes for each doors control.
Run time
– relay closing time in monostable mode (time of electrical lock
opening)
Source -
Synchronize from time table - it is selected time plan for relay and 2 options
are available:
Monostable, then allways when setup time period in time plan is suitable
and time plan is active is perform closing for preprogrammed closing
time.
Bistable, then allways when setup time period in time plan is suitable and
time plan is active the relay is closed and out of those conditions is
open.
Synchronize with relay 1
– 4 – relay closing starts closing of the same or
other relay. Example for usage is sliding gate control, where by partly
opening you can create passage
– door substitution. For this mode
relay must close for 1 sec in 2 times in sequence. Where period
between closing is created passage.( for example 6sec).
The setting
make that for relay 1 select monostable mode with time closing 1 sec,
synchronization with relay 1 and synchronization delay 7 sec
. In case
you need setup situation that for one code (55) relay 1 close 2 pulses
in sequence
– passage creation and by second code (56) gate will be
closed then use not connected relay 4 for synchronization.
Setting of
relay 1 is monostable, closing time 1 sec, synchronization with relay 4
and synchronization delay 7 sec. Codes for relay 1 closing are 55 and
56. The relay 4 we setup as monostable, closing time 1 sec, closing
code 55.
By synchronization you can create different closing combination.