IP VarioBell
- installation and operating instructions
45
Synchronize delay
– time between synchronization start and its evaluation.
Usage for example in more relays closing combination for one code
Active on call
– options are
none (calling has no influence for relay status)
incoming call
– relay closed during incoming call. The monostable for
preprogrammed time. The bistable permanently for all call duration.
outgoing call
– relay closed during outgoing call. The monostable for
preprogrammed time. The bistable permanently for all call duration.
Both call
– relay closed during every call. The monostable for
preprogrammed time. The bistable permanently for all call duration.
Acoustic tone
– In case of need you can simulate relay closing by sound signal.
This feature is usefull mainly in monostable mode in case of PoE
feeding of low consumption electrical lock by DC power supply. This
sound simulates typical buzzing of electrical lock. Further option is
record voice message to SD card for blind people with information
about electrical lock opening.
This option has yet another hidden meaning, the LED on the front panel
when you turn the acoustic signal indicates the switch is activated lights
red + green.
Activate by protocol HTTP
– relay status is possible change by sending HTTP
request (GET request) to IP adress of door entry. To get working this
feature you must permit by parametr relay control by HTTP. Request
for door entry must be in following format (you can test by variol web
browser):
command relay switch:
IPaddress / relay_control? R = on where r = number of relays 1-4
E.g. http://192.168.1.250/relay_control?1=on - switches on relay 1
(doorphone to the default IP address)
command to releasing relay:
IPaddress / relay_control? R = off where r = number of relays 1-4
E.g. http://192.168.1.250/relay_control?1=off - switches off relay 1
(doorphone to the default IP address). Releasing the relay is important
in the bistable switch mode.
Security output code
– relay output is close/open in default. This static status
is dangerous in case of unauthorised enter for example by door entry
demaged and short circuit wires of power supply and electrical lock.
Defence is using module COSW which you connect to electrical lock
wires
– closest to electrical lock. For relay closing is sends in such
connection pulses set and when setup code at COSW match with code
of this parametr relay is closed.
Caution
–
do not fill code when electrical lock without COSW is
connected. It can demage relay in door entry IP Fermax!
Direct ON button
– when you fill up button number then this number will work
as
departure button
only. Eventually might be used relay output for