ENG
9
VII - SET OF PIECES OF VERMICULITE FOR STOVES VALLE, BRITO, DENIA & GRANADA
All the interior of the combustion chamber is covered with a removable body made from vermiculite. The vermiculite set is shown in
figure 6. All the pieces are removable and replaceable.
VIII - SMOKE OUTLET
Smoke outlet can be laid either in horizontal or in vertical position by changing the elbow
location (in models DENIA & GRANADA). If you choose the vertical outlet you have to take
away the semicircular lid, as shown in figures 7. Please, for stoves VALLE & BRITO you must
see the drawing in figures 7.
Make the connection from the elbow using a pipe or a chimney connector. The following
materials are forbidden for the connection:
aluminium, aluminised steel and galvanised
steel
. FERLUX can provide all the necessary accessories for installation (ask your supplier).
IX – ADVICES FOR MAINTENANCE
- Clean the exterior surface with a damp cloth. Do not use cleaning products that may damage the paintwork and / or produce unpleasant fumes.
- The combustion chamber door must be kept shut except when lighting the fire or adding wood to the fire.
- The ashtray must also be kept shut except when removing ashes.
- Do not use the fire in a total isolated room- it is important to allow a constant flow of fresh air.
- Do not attempt any unauthorised modification to the fireplace.
- Only use spare parts approved by the manufacturer.
- Periodically clean the appliance, the flue connector and the chimney pipe, and check there is no obstruction on them after a large period without using.
X - SAFETY ADVICE
−
Never use the fire when there are inflammable gases in the room.
−
The combustion air inlets must not be modified under any circumstance.
−
The grill air vents of the fireplace must be kept clear of any obstruction at all times.
−
To avoid the risk of accidental fires, we advice to take protection measures as keeping flammable objects well away from the appliance and thermal insulation. The
minimum distance from inflammable materials must be at least 2 m to the front of the fireplace. Keep the same security distance with damp clothes put close to the fire to
dry.
−
The fireplace and surround must not be installed in a place where there is heavy movement.
−
To avoid accidents, tell the children that the fireplace gets very hot when is being used and advise them not to touch it.
−
Do not put the residual ashes on top of materials that could burn such as paper cardboard or wood. The ashes can remain hot for a very long time.
−
The first time the fire is used it is important not to touch it until it is cold to allow the paint to seal. It is normal when the fire is first used for smells and smokes to be given off
until the paint/joints are well-sealed. We therefore recommend that windows are left slightly open during this time.
−
It is dangerous to overheat the appliance.
−
Blazing fires of twigs, kindling, vine shoots, straw, cardboard etc. are definitely not advisable.
−
Do not burn refuse, plastics, etc.
−
Do not build the fire high.
−
The combustion chamber must not be removed or taken apart.
−
Never
use the appliance without the ashtray cleaned up, in order to avoid the deformation of the cast iron grill/base, which will cancel the guarantee.
−
To protect the appliance of water accumulation, avoid humidity in the outlet pipe as well as the entry of water into the fireplace.
−
The climatological conditions of the place can affect to the good working of the equipment and security of the users, particularly when there is a potential risk of frosts.
XI - TROUBLE SHOOTING
ANOMALY
SOLUTIONS
THE GLASS BECOMES
DIRTY QUICKLY
•
Check the humidity of fuel.
•
Open the front air vents
THE FIREPLACE DRAWS
TOO MUCH
•
Shut the damper
•
Ask your supplier
THE FIREPLACE DOESN’T
DRAW WELL, WITH
EMISSION OF FUMES INTO
THE ROOM
•
Check the fireplace and the chimney (see the user’s manual).
•
Remove any obstruction
•
Sweep the chimney
•
Open the damper
THE FUEL DOESN’T BURN
WELL
•
Check if the fuel is damp
•
Empty the ashtray
•
Remove any obstruction in the air vents
•
Open the damper
FIGURE 6
VERTICAL OUTLET
HORIZONTAL OUTLET
LID REMOVAL
IN CASE OF A FIRE IN THE FIREPLACE OF CHIMNEY, TAKE
THE FOLLOWING MEASURES:
INMEDIATELY CLOSE ALL THE AIR VENTS:
A)
Front door
B)
Ashtray
C)
Primary air vents
FOLLOWING INFORM THE FIREFIGHTING LOCAL
AUTHORITIES ABOUT THE EVENT
FIGURES 7
Change smoke outlet in models DENIA & GRANADA:
Change smoke outlet in models VALLE & BRITO:
1
2
3
4
5
6