39
IF THE GLASS OF THE DOOR IS ACCIDENTALLY BROKEN DURING
CLEANING, DO NOT LIGHT THE HEATER AND CONTACT THE
TECHNICAL SUPPORT SERVICE SO THAT THEY CAN REPLACE IT
(Only an original spare part can be used since the glass has special
properties)
9. PROBLEMS, MESSAGES, ERRORS AND SOLUTIONS
The heater uses messages and alarms that appear on the display to inform the user of certain situations and/or problems that
hinder the correct operation of the unit.
The electronic control board, via various devices and sensors connected to it, receives data. It returns a message or alarm
when the values fall outside certain ranges.
This does not mean that the heater has a problem, but rather, on many occasions, it brings issues to light regarding the fuel,
installation, lack of cleaning, or something else.
Carefully read everything that is explained in this section because as well as helping you to interpret the messages and alarms
that may be shown, it lists possible causes and even some remedial measures that can be taken.
THE APPEARANCE OF MESSAGES AND ALARMS IS PART OF
NORMAL OPERATION BECAUSE THEY SERVE TO NOTIFY THE
USER OF SPECIFIC SITUATIONS.
THEY ONLY POINT TO A PROBLEM WITH THE HEATER WHEN
THEY ARE CAUSED BY THE DEFECTIVE OPERATION OF ONE OR
MORE OF THE COMPONENTS OF THE HEATER THAT HAVE LEFT
THE FACTORY IN A DEFECTIVE CONDITION
9.1 PROBLEMS
Some advice appears below so that you can make sure that everything is correct before lighting the heater and assuredly
begin the start-up process:
•
Check that the installation has been effected in accordance with any regulations in force and in accordance with
the instructions from the manufacturer. (see chapter 5. INSTRUCTIONS FOR INSTALLATION).
•
Only use fuel that is appropriate and try to keep the level in the hopper to half-full, at minimum. (see chapter 4.
FUEL).
•
If the fuel has spent a long time in the hopper, it is appropriate to remove it because it could have absorbed
moisture from the air and no longer be suitable for use. If damp wood pellets are used, they could affect the normal
operation of the heater.
•
Carry out the maintenance instructed by the manufacturer, not forgetting to clean the brazier every 10-12 hours (at
most) of operation. After cleaning, replace it correctly.
Содержание AROA 10
Страница 1: ...Quality of Life MANUAL FOR THE USER AND INSTALLATION AIR RANGE COD 0153 R2 INGL S...
Страница 2: ...2...
Страница 11: ...11 MODEL FLORA 7 8 kW MODEL NEREA 8 10 kW...
Страница 12: ...12 MODEL NATALIA 10 kW MODEL AROA 8 10 kW...
Страница 13: ...13 MODEL NEREA 12 15 kW MODEL LUNA 8 10 kW...
Страница 14: ...14 MODEL ESTELA 12 15 kW MODEL G NESIS 6 8 kW...
Страница 46: ...46...