17
5.2.1 PROTECTING THE FLOOR
If your flooring is flammable (parquet, floating platform) or sensitive to heat, it is
necessary to place a protective layer that separates the heater from the floor.
This protection must be make of a material that is resistant to fire, such as marble,
steel plating, slabs, etc. This material must be capable of bearing load without being
deformed or broken by the weight of the heater.
This protection must be at least two mm thick and must project at least 150 mm
beyond the heater on both sides and to the rear, and 300 mm at the front.
5.2.2 MINIMUM SAFETY DISTANCES
The following figures show the minimum safety distances that must always be observed.
Safety distances to
flammable material
Safety distances to non-
flammable material
A
200 mm
100 mm
B
200 mm
100 mm
C
1500 mm
750 mm
D
500 mm
200 mm