31
15. ERROR REPORTING, SIGNALING, DELETING
Each connected device reports its alarms directly to the gateway. These errors may be with the
following signaling:
Low battery
• Battery connected to an energizer - the battery symbol flashes when the voltage drops
below 12 V. In addition, if the voltage drops below 11.6 V, the siren will sound (if sound is
enabled, see page 21).
• Battery of the monitor - an alarm is indicated when the voltage of the battery drops below
10%.
• Decrease of the output voltage from the energizer or decrease of the voltage at the
measured point by monitor below the set limit –
the symbol with kV will flash and the
siren will sound (if it is allowed sound, see page 21).
• Signal Loss –
Dashes are displayed instead of all energizer´s or monitor´s values and the
signal level symbol flashes and the siren sounds (if sound is enabled, see page 21).
» Signaling
If any of these errors occur, the gateway signals the fault as follows:
1.
The information that indicates the error flashes on the gateway display.
2.
The output relay closes. It causes that external alarm is activated, if is connected and set
(see page 24, Alarm mode)
3.
If audible alarms are enabled, the siren will sound (see page 21 for sound settings
and Alarm mode set, see page 24).
» Confirming and deleting errors
The alert will be activated until acknowledged by the user.
• Deactivating the audible alarm and opening the output relay can be done by pressing any key.
• To completely clear gateway errors (error segments blinking), press the
key.
• Subsequently, the gateway will update the information and if a device fault is still detected,
the alarm is reactivated.
• If the fault is remedied, the error symbol stops flashing, an audible alarm, and an output
relay are deactivated.