15. ERROR REPORTING, SIGNALING, DELETING

Each connected device reports its alarms directly to the gateway. These errors may be with the 
following signaling:

Low battery 

• Battery connected to an energizer - the battery symbol flashes when the voltage drops 

below 12 V. In addition, if the voltage drops below 11.6 V, the siren will sound (if sound is 
enabled, see page 21).

•  Battery of the monitor - an alarm is indicated when the voltage of the battery drops below

10%.

• Decrease of the output voltage from the energizer or decrease of the voltage at the 

measured point by monitor below the set limit  –

  the symbol with kV will flash and the 

siren will sound (if it is allowed sound, see page 21).

• Signal Loss –

 Dashes are displayed instead of all energizer´s or monitor´s  values and the 

signal level symbol flashes and the siren sounds (if sound is enabled, see page 21).

» Signaling

If any of these errors occur, the gateway signals the fault as follows:

1. 

The information that indicates the error flashes on the gateway display.

2.

 The output relay closes. It causes that external alarm is activated, if is connected and set 

(see page 24, Alarm mode)

3.

 If audible alarms are enabled, the siren will sound (see page 21 for sound settings 

 

and Alarm mode set, see page 24).

» Confirming and deleting errors

The alert will be activated until acknowledged by the user.
•   Deactivating the audible alarm and opening the output relay can be done by pressing any key.

•   To completely clear gateway errors (error segments blinking), press the  

  key.

•   Subsequently, the gateway will update the information and if a device fault is still detected, 

the alarm is reactivated.

•   If the fault is remedied, the error symbol stops flashing, an audible alarm, and an output 

relay are deactivated.

Содержание GW100

Страница 1: ...or MX10 UP TO DATE INFORMATION Online up to date information on all devices Control and monitor through mobile application PHONE CONTROL ALARM SIGNALLING Immediate problem alert sent to the phone and...

Страница 2: ...60335 1 I CSN EN 55014 1 I CSN EN 55014 2 1 CONTENT 1 Content 2 2 Important recommendations 3 3 Package content 3 4 Introduction 4 5 List of main advantages 5 6 Gateway installation and fence connecti...

Страница 3: ...qualified personnel Please dispose all waste in accordance with your country s code of practice The displayed output voltage tolerance is 10 2 IMPORTANT RECOMMENDATIONS 3 PACKAGE CONTENTS FENCE WiFi G...

Страница 4: ...nged format the user has the option to set limit for triggering alarm for each fence and monitor which will generate alert if the set limits are exceeded Energizers may be remotely switched off switch...

Страница 5: ...ll essential information together in one device Large fully graphic LCD display Overview screen with information relating to all energizers and monitors Detailed display of parameters of each energize...

Страница 6: ...1 12 13 15 17 9 6 GATEWAY INSTALLATION AND FENCE CONNECTION Before installing the gateway please read all the security instructions in this manual carefully For wall mounting use the enclosed screws t...

Страница 7: ...7 13 Tensioner 14 IInsulators 15 Warning sign Gateway GW100 3 4 5 14 2 CLOUD 16 Gate 17 Insulator of gate Monitor MX10 RF energizer G2...

Страница 8: ...gnaling Power adapter connector SMA connector for antenna connection Radio RF antenna THE DEVICE CAN DISTINGUISH TWO TYPES OF PRESS Short press Long press more than 1 s 7 DESCRIPTION OF THE DEVICE 7 1...

Страница 9: ...il screen Short press asking the selected device for up to date information In case of error signaling confirmation and deleting alerts Long press setting the pulse voltage limit If it falls below the...

Страница 10: ...10 7 2 Back side Backup battery Socket for connecting the backup battery connector...

Страница 11: ...erting backup battery 9 6 V backup battery power supply used in the event of mains power failure is able to supply the device for up to one day however it depends on the device settings such as backli...

Страница 12: ...evice energizer To select pairing press and hold 1 Use the arrows to move to Pairing and by press the key you will get to the Device Manager where you work with the device 2 Switch the energizer to pa...

Страница 13: ...e Pairing The gateway GW100 also enables remote pairing for energizers energy DUO RF EDX This me ans that you do not have to have a energizer directly at the gateway to be able to pair it Pai ring can...

Страница 14: ...ED flashes red Then reattach the magnet to the target on monitor and hold until both LEDs green and red flashes on the monitor The monitor is now in pairing mode Place the device close to the gateway...

Страница 15: ...A L only a designation that is not yet used is offered Associated to see explanation on page 16 monitor Subordination 7 Editing for entering press by arrows choose marking and confirm 8 Press the but...

Страница 16: ...rrows to move to desired item 3 By short press key you confirm choice of the monitor 4 After confirmation a pop up window will appear showing the current settings 5 Subordination is indicated on the l...

Страница 17: ...diting is now signaled by blinking of the entered value which can be set by arrows Note the values that you cannot choose are skipped automatically 8 The change can be confirmed by short press of key...

Страница 18: ...ordination means that the monitor check the same fence where the voltage is being generated by superior energizer If the fence is intentionally switched off no recall occurs alarm on the monitor In th...

Страница 19: ...audible alarm see page 21 Indication of last device response Under each device is a bargraph which signals the time since the last sent informati on about the status of the remote device The transmiss...

Страница 20: ...rgizer s performance according to the current load impedance of the fence system Only for EDX series energizers MAC address fo device energizer monitor Current load impedance of the fence displayed in...

Страница 21: ...Sound settings Sound setting gateway The volume of the buttons is adjustable in four levels off level 1 2 and 3 Enable audible alarms on the gateway ON OFF Use the arrows to move between options chan...

Страница 22: ...the backlight to turn off automatically from the last key press selectable from 5 to 55 seconds or Never by a letter on the display for the constant backlight Procedure for setting the gateway displa...

Страница 23: ...d paired devices at set intervals 60 min is set for all devices by default The user is able to set shorter intervals in order to be notified of a signal failure earlier Interval options 15 min 30 min...

Страница 24: ...ation and thus to the mobile application and web browser This option changes the current gateway MAC address This function will be used particularly when the GW100 gateway is bought from another user...

Страница 25: ...st be repeated If everything has been carried out correctly the MAC address will be overwritten in the gateway s memory and new PIN will be generated Both data are displayed on the screen This screen...

Страница 26: ...ired GW100 installation site must have good Wi Fi cover 2 In order to create a new connection the SSID line must be blank if yes then proceed as per Point 3 If no using select Reset SSID line in the p...

Страница 27: ...Fi connect Scan the displayed QR Code with your mobile phone Confirm the Wi Fi login information named gateway on your mobile phone This generates connection in the phone even if the Internet is not a...

Страница 28: ...ssible to log in manually Turn on any web browser on your phone and manually type the IP address into the address search bar 192 168 4 1 List of available Wi Fi will appear and then proceed as per Poi...

Страница 29: ...tivated and managed on the web browser or in the mobile applica tion For this MAC address and Pin unique codes for your GW100 device are required These may be found in the package contents label on th...

Страница 30: ...l connected devices displayed according to the parent gateway ONLINE ALARMS In the event that exceptional fault condition arises imme diate warning is sent to the phone and e mail MAP BASE For easy or...

Страница 31: ...d the signal level symbol flashes and the siren sounds if sound is enabled see page 21 Signaling If any of these errors occur the gateway signals the fault as follows 1 The information that indicates...

Страница 32: ...erated on low voltage only from the battery Replace the battery and reset to factory settings see manual 16 RESET TO FACTORY SETTINGS Resetting includes Deleting all paired devices Formating empty pos...

Страница 33: ...33 120 mm drill here drill hole 6 mm for the plug 18 HOLE DRILLING TEMPLATE...

Страница 34: ...34...

Страница 35: ...tee is valid in case of correct use in accordance with the instructions for use It expires in case of interferences by unauthorized persons and in case of using spare parts of foreign origin All defic...

Страница 36: ...u 06052021 VNT electronics s r o Dvorska 605 563 01 Lanskroun Czech Republic info fencee eu 420 730 893 828 Servis 420 730 893 827 fencee cz fenceeczech Electric fencing www fenceefarm com Free app fe...

Отзывы: