1. Meter S40-R
Panel meter 72x36mm for ratiometric and potentiometer signals
Panel meter for ratiometric and potentiometer signals, from 3
wire transducers. The meter pr5V (max. 35mA) and
a 0V signal, and receives from the transducer a signal be-
tween 0 and 5V. Scalable reading. 10 segment linearization.
Instrument with reduced 72x36mm size. Resolution 4 digits
with negative sign (“
9999”
/“
-1999
”).
Management for up to 2 alarms with 1 or 2 setpoints each,
with hysteresis and delays. Provides memory for maximum
and minimum, left zeros, display on selectable steps, fixed
digits, recursive display filter, password, brightness control,
“
measure
” function (visualizes input signal without scaling),
offset and signal high autocorrection (assigns the actual
signal to the low or high reading), “
peak&hold”
function and
password.
Power options with universal AC and DC ranges, and space
for 2 additional control and/or signal retransmission modules.
Standard IP54 front protection, with optional upgrade to IP65
protection.
Connections via plug-in screw terminals and configuration
via three front push-buttons. For application on industrial
environments.
S40
R
H
Model
Power
-H
(85-265 Vac/dc)
-L
(11-60 Vdc
and 24/48 Vac)
-
-
-
---
Option1
-R1
(1 relay)
-AO
(Analogue Output)
-
(empty)
-
---
Others
-65
(IP65)
-
(empty)
---
Option2
-R1
(1 relay)
-AO
(Analogue Output)
-
(empty)
-
1.1 Order reference
Index
1. Meter S40-R . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Order reference . . . . . . . . . . . . . . . . . . . 2
1.2 Front View . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear View . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power Connections . . . . . . . . . . . . . . . . . 3
1.5 Input signal connections
1.6 Technical data. . . . . . . . . . . . . . . . . . . . 4
1.6 Technical data (cont.) . . . . . . . . . . . . . . . . 4
1.7 Mechanical dimensions (mm). . . . . . . . . . . . 4
1.8 Operating the menus . . . . . . . . . . . . . . . . 5
1.9 Default factory configuration
. . . . . . . . . . . . . . . . 6
1.10 Configuration menu (cont.)
1.10.6 Display . . . . . . . . . . . . . . . . . . . . . 8
1.10.7 Tools . . . . . . . . . . . . . . . . . . . . . . 9
1.10.8 Menu OptX - Options. . . . . . . . . . . . . . 9
1.11 Messages and errors . . . . . . . . . . . . . . . 9
1.12 Information menu . . . . . . . . . . . . . . . . 10
1.12.1 Information menu . . . . . . . . . . . . . . 10
1.13 Accessing the instrument . . . . . . . . . . . . 10
1.14 Warranty . . . . . . . . . . . . . . . . . . . . . 11
1.15 Installation precautions
1.16 CE declaration of conformity . . . . . . . . . . 11
2. Output and control modules . . . . . . . . . . . . . 12
2.1 Module R1 . . . . . . . . . . . . . . . . . . . . 12
2.2 Module AO