1. Meter S40-R

Panel meter 72x36mm for ratiometric and potentiometer signals

Panel meter for ratiometric and potentiometer signals, from  3 
wire transducers. The meter pr5V (max. 35mA)  and 
a 0V signal, and receives from the transducer a signal be-
tween 0 and 5V. Scalable reading. 10 segment linearization.

Instrument with reduced 72x36mm size. Resolution 4 digits 
with negative sign (“

9999”

/“

-1999

”). 

Management for up to 2 alarms with 1 or 2 setpoints each, 
with hysteresis and delays. Provides memory for maximum 

and minimum, left zeros, display on selectable steps, fixed 

digits, recursive display filter, password, brightness control, 

measure

” function (visualizes input signal without scaling), 

offset and signal high autocorrection (assigns the actual 

signal to the low or high reading), “

peak&hold” 

function and 

password.

Power options with universal AC and DC ranges, and space 
for 2 additional control and/or signal retransmission modules.

Standard IP54 front protection, with optional upgrade to IP65 
protection.

Connections via plug-in screw terminals and configuration 

via three front push-buttons. For application on industrial 
environments.

S40

R

Model

Power

-H 

(85-265 Vac/dc)

-L 

(11-60 Vdc

 

and 24/48 Vac)

-

-

-

---

Option1

-R1 

(1 relay)

-AO 

(Analogue Output)

-

(empty)

-

---

Others

-65 

(IP65)

-

(empty)

---

Option2

-R1 

(1 relay)

-AO 

(Analogue Output)

-

(empty)

-

1.1 Order reference

Index

1. Meter S40-R   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 2

1.1 Order reference . . . . . . . . . . . . . . . . . . . 2
1.2 Front View  . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear View . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power Connections . . . . . . . . . . . . . . . . . 3
1.5 Input signal connections 

 . . . . . . . . . . . . . . 3

1.6 Technical data. . . . . . . . . . . . . . . . . . . . 4
1.6 Technical data (cont.) . . . . . . . . . . . . . . . . 4
1.7 Mechanical dimensions (mm). . . . . . . . . . . . 4
1.8 Operating the menus  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

1.9 Default factory configuration

 

 . . . . . . . . . . . . 5

1.10 Configuration menu

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 6

1.10 Configuration menu (cont.)

 

 . . . . . . . . . . . . 7

1.10.1 Input menu . . . . . . . . . . . . . . . . . . . 8
1.10.2 Scaling  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 8
1.10.3 Decimal point. . . . . . . . . . . . . . . . . . 8
1.10.4 Auto correction . . . . . . . . . . . . . . . . . 8
1.10.5 Alarms   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 8

1.10.6 Display  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 8
1.10.7 Tools   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 9
1.10.8 Menu OptX - Options. . . . . . . . . . . . . . 9

1.11 Messages and errors  . . . . . . . . . . . . . . . 9
1.12 Information menu   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 10

1.12.1 Information menu  . . . . . . . . . . . . . . 10

1.13 Accessing the instrument   .   .   .   .   .   .   .   .   .   .   .   . 10
1.14 Warranty . . . . . . . . . . . . . . . . . . . . . 11
1.15 Installation precautions 

 . . . . . . . . . . . . . 11

1.16 CE declaration of conformity  . . . . . . . . . . 11

2. Output and control modules   .   .   .   .   .   .   .   .   .   .   .   .   . 12

2.1 Module R1  . . . . . . . . . . . . . . . . . . . . 12
2.2 Module AO 

 . . . . . . . . . . . . . . . . . . . . 12

2.3 Modules R2, R4. . . . . . . . . . . . . . . . . . 13

Содержание S Series

Страница 1: ...earization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Universal AC and DC po...

Страница 2: ...dard IP54 front protection with optional upgrade to IP65 protection Connections via plug in screw terminals and configuration via three front push buttons For application on industrial environments S4...

Страница 3: ...wer line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9 0 1 2...

Страница 4: ...ec 0 to 99 signal Power Power H 85 to 265 Vac dc Power L 11 to 60 Vdc and 24 48Vac Consumption 4W Isolation 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds Configuration 3 f...

Страница 5: ...ue outputs The Information Menu is for information only and it does not accept changes on the displayed information To enter the In formation Menu press the UP button It is not affected by the PASSWOR...

Страница 6: ...ut High Display High Decimal Point Alarm1 Setpoint Hysteresis Delay Setpoint2 Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High R...

Страница 7: ...zation Password Version Points Enter signal values Input and associated display val ues Display for each linearization point Then activate Act to On In case of error verify the points data Select pass...

Страница 8: ...alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is 1000 and 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Function...

Страница 9: ...al while hold is active 1 10 7 Tools 1 10 8 Menu OptX Options When the instrument detects that the displayed value does not correspond to the expected value the display will flash and alternate with a...

Страница 10: ...he configured input signal range 4 20mA 0 10Vdc and the values for input low ILo display low dLo input high IhI and display high dhI Maximum MAX Value of the maximum display Minimum MIn Value of the m...

Страница 11: ...to the 61010 1 CE security regulation and is designed for applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of meas...

Страница 12: ...AO modules can be installed in one S Series panel meter For more information see document 2657_S40_OPTIONAL_ MODULES at www fema es Module with 1 relay Up to a maximum of two R1 modules can be instal...

Страница 13: ...contacts Common NO NC Maximum current 6A resistive load each relay Voltage 250 Vac continuously Installable at slot Opt 1 R2 fills OPT1 R4 fills OPT1 and OPT2 Terminal Plug in screw terminals pitch 3...

Страница 14: ...User s Manual S40 R FEMA ELECTR NICA Page 14 T H I S P A G E B L A N K...

Страница 15: ...User s Manual S40 R FEMA ELECTR NICA Page 15 T H I S P A G E B L A N K...

Страница 16: ...other products ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 72...

Отзывы: