6.1.15. [0xA1] Write Config Block
This command writes one config block of the
i-scan
memory model (see
ANNEX G: Memory Model I-
Code 1 Transponders
).
REQUEST-DATA
4
5
6...13
14
15...18
0xA1
MODE
UID
CB-ADR
CB
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b001
addressed
UID:
Read-only serial number of the Transponder.
CB-ADR:
Address of the config block to be read from the Transponder.
CB:
Config block to be written to the Transponder.
Note:
•
This command is only available for I-Code 1 Transponders.
•
The command is not available if the Reader is set to original I-Code Memory Model.
(see
3.5. CFG4: Transponder Parameters
, I-Code-Mode).
To write the Config Block 0,1,2 can now be done with Write Multiple Blocks [0x24] on the
original I-Code Address 2,3,4.
When using ISO15693 Transponders the command
6.1.3. [0x22] Lock Multiple Blocks
should
be used.