OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH
Page 101 of 131
H60301-3e-ID-B.doc
9.1.2.
Fujitsu (MB89R116)
IC manufacturer identifier: 0x08
Memory organization: 256 x 8 Byte = 2kBit
Number of blocks
256 (user area: 0 – 249)
Block size
8 byte
Command
Code
Function
Mode
Comment
non-ad-
dressed
addressed
select
0x01
Inventory
√
-
-
0x02
Stay Quiet
√
-
√
-
0x22
Lock Multiple Blocks
√
√
√
√
WR-OPTION = 0 or 1
0x23
Read Multiple Blocks
*
√
√
√
√
DB-Size = 8
Security Status is always
0x00
0x24
Write Multiple Blocks
**
√
√
√
√
DB-Size = 8,
WR-OPTION = 0 or 1
0x25
Select
√
-
√
-
0x26
Reset to Ready
√
√
√
√
0x27
Write AFI
√
√
√
√
WR-OPTION = 0 or 1
0x28
Lock AFI
√
√
√
√
WR-OPTION = 0 or 1
0x29
Write DSFID
√
√
√
√
0x2A
Lock DSFID
√
√
√
√
0x2B
Get System Information
√
√
√
√
0x2C
Get Multiple Block Security
Status
√
√
√
√
*
The Custom Specific Commands Read Multiple Blocks Unlimited [
0xA5
] will be used auto-
matically by the Reader.
**
The WR-OPTION will be set automatically by the FEIG Readers if the RW-OPTION parameter
in “
3.5. CFG4: Transponder Parameters
” is set to “00: automatically set”. Up to two blocks
of data can be written for one request.
•
ASK SUB-CARRIER must be configured in the reader (see: “
3.5. CFG4: Transponder Pa-
rameters
”)