OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 57 of 118
H01000-5e-ID-B.doc
6.1.4. [0x23] Read Multiple Blocks
This command reads one or more data blocks.
The supported ISO15693 Host commands depends on the different ISO15693Transponder types,
which are described in chapter
9.1. Supported ISO15693 Host commands for ISO15693 Transpond-
ers
.
REQUEST-DATA
4
5
(6...13)
6 / (14)
7 / (15)
0x23
MODE
UID
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
ERROR
RESPONSE-DATA
5
6
7
8...n
DB-N
DB-SIZE
SEC-STATUS
DB
Repeated DB-N times
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
SEC
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
SEC:
b0
SEC-STATUS always = 0x00
b1
security status of followed data block in SEC-STATUS
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DB-ADR:
First block number to be read. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface transmit buffer size
TX-BUF. The maximum number of DB-N is:
(TX-BUF - 10 )/(DB-Size+1)
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.