H01000-5e-ID-B.doc
Driver-
Installation
•
The already installed
OBID
®
DLLs are valid for all
OBID i-
scan
®
readers with
SCI-Interface.
•
Each Reader needs there own driver installa-
tion. Because of the unique serial number (De-
vice ID).
Reader-
addressing
•
Bus Address 0-255
•
Device ID (Serial number)
Power
supply
•
ID
ISC.MR100
-> 12-24V
via socked X2 (Interface)
•
ID
ISC.PR100
-> 12-24V
•
ID
ISC.PRH100
-> 5V
•
ID ISC.MR101-USB -> 12-24V
via separate socked X1
•
ID
ISC.PR101-USB
-> 5V (High powered USB)
CFG1
COM-
Interface
•
Byte 0: BUS-ADR
•
Byte 2: Baudrate
•
Byte 3: Dataformat
•
Byte 0: not used
•
Byte 2: not used
•
Byte 3: not used
Software
Support for
operating
systems
•
Windows
®
, Windows CE
®
,
Linux
®
•
Windows
®