OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 34 of 118
H01000-5e-ID-B.doc
SEP-CHAR:
Selects the separation character between two data types for the send data.
Bit:
7
6
5
4
3
2
1
0
Function
USER
‘ ‘
‘,‘
‘;’
TAB
CR
LF
CR+LF
ASCII
Hex
CR+LF
0x0D and 0x0A
CR
0x0D
LF
0x0A
TAB
0x07
‘;’
0x3B
‘,’
0x2C
‘ ‘
0x20
none
0x00
USER
user defined in SEP-USR
Note:
Only one option could be selected.
SEP-USR:
User defined separation character.
END-CHAR:
Selects the end character between two data types for the send data.
Bit:
7
6
5
4
3
2
1
0
Function
USER
‘ ‘
‘,‘
‘;’
TAB
CR
LF
CR+LF
ASCII
Hex
CR+LF
0x0D and 0x0A
CR
0x0D
LF
0x0A
TAB
0x07
‘;’
0x3B
‘,’
0x2C
‘ ‘
0x20
none
0x00
USER
user defined in END-USR1...3
Note:
Only one option could be selected.
USB-Reader: The End Character will be transferred any time, even if the buffer is to
small for the data.