OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 48 of 118
H01000-5e-ID-B.doc
5.8. [0x71] Set Output
The command [0x71] is used for temporary limited or unlimited activation of the digital outputs or dis-
plays (LED, beeper) of the Reader.
Each output takes on the state defined by the byte "OS" for the period of time specified in the protocol.
The flashing frequency is defined by the byte "OSF". Via this protocol, the beeper and the LEDs can
be switched on or off for the indicated period of time. If the Reader receives a protocol "Set Output", all
times that have been active until then are overwritten by the new times specified in the protocol if they
are
>
0.
Host
→
Reader
1
2
3
4,5
6,7
13
COM-Adr
[0x71]
OS
OSF
°
8,9
10,11
12,13
ª
OS-Time
0x00
CRC16
Host
←
Reader
1
2
3
4
5,6
6
COM-Adr
[0x71]
Status
1
CRC16
OS:
The word OS (Output State) defines the status of the signal emitters (LEDs and beeper) dur-
ing the time defined in "OS-time". The signal emitters can be selected single or in a group.
Bit:
15
14
13
12
11
10
9
8
Function:
0
0
0
0
0
0
0
0
°
7
6
5
4
3
2
1
0
ª
0
0
Beeper mode
(only PRH100)
LED red
mode
LED grn
mode
LED grn-/LED red-/Beeper-mode:
b00
UNCHANGED
OS-Time has no effect on the status of the signal emitter
b01
ON
Signal emitter for OS-Time = active
b10
OFF
Signal emitter for OS-Time = inactive
b11
FLASH
Signal emitter for OS-Time = with "OSF" alternating
1
see ANNEX D: Index of Status Bytes