OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 70 of 118
H01000-5e-ID-B.doc
6.1.14. [0xA0] Read Config Block
This command reads one config block of the
i-scan
memory model (see
ANNEX G: Memory Model I-
Code 1 Transponders
).
REQUEST-DATA
4
5
6...13
14
0xA0
MODE
UID
CB-ADR
RESPONSE-DATA
5...8
CB
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b001
addressed
UID:
Read-only serial number of the Transponder.
CB-ADR:
Address of the config block to be read from the Transponder.
CB:
Requested config block.
Note:
•
This command is only available for I-Code 1 and Tag-it HF Transponders.
•
The command is not available if the Reader is set to original I-Code Memory Mode.
(see
3.5. CFG4: Transponder Parameters
, I-Code-Mode).
To read the Config Block 0,1,2 can now be done with Read Multiple Blocks [0x23] on the
original I-Code Address 2,3,4.