OBID
i-scan
®
Application-Note
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 25 von 26
N50101-0e-ID-B.doc
4.4. Setting Buffered Read Mode
„Buffered Read Mode“ is the normal operating mode of the Reader. Here the Reader reads the
label data at maximum speed and stores the data in a ring buffer in the Reader. These can then be
queried by the host. To activate „Buffered Read Mode“ proceed as follows.
Table 13: Activating Buffered Read Mode
Step
Procedure
Note
1
Select „Configuration“
menu
2
System Parameters
CFG15:
Antenna Multiplexing
Enable Multiplexing
Switching Condition
b0: after no response
No. of Input Channels
b10: 2Inputs(Dual Mode)
No. of Output Channels
2 (4 antennas)
3 (6 antennas)
3
„Write“ to set parameters
4
System Parameters
CFG11:
Buffered Read Mode:
TR.DATA
Serial Number
VALID-TIME
300 x 100 ms
5
„Write“ to set parameters
6
System Parameters
CFG10: General
Enable Buffered Read
Mode
Enable Anticollision Select
Mode
7
„Write“ to set parameters