Check if the condensate is drained from the air tank and drain plug is closed.
•
Check the condition of safety vent, air-tank and all pressure accessories.
•
If is the air filter dirty, you should replace or clean it.
•
Check if the air hose connect properly.
START / TURNING OFF
•
Start the machine by push of the bottom on the main switch
(fig. 6D).
•
Turn off the machine by push of the bottom on the main switch.
1.
Start the machine, leave the air-tank get the pressure and check if there is some air leakage.
2.
Adjust the operation pressure needed.
3.
If is the air-tank well pressured, the machine is automatically turned off.
4.
If is the pressure too low, the machine is automatically started.
5.
Turn off the machine always after the work. Open the ventilating of the tank and de-aerate and drain
the accumulated condensate.
MAINTENANCE AND STORAGE
CAUTION!
To ensure proper functioning of the machine, it is necessary to have it checked and adjusted by
qualified personnel in an authorized service centre at least once a year.
Proper maintenance is essential for safe, economic and trouble-free operation of the machine.
Failure to follow the maintenance instructions and safety precautions may cause serious injury or death.
Always follow the procedures, safety precautions, recommended maintenance and recommended checks
mentioned in this manual.
WARNING
Prior to any work on the machine (maintenance, inspection, replacement of accessories, servicing) or
before storing it, ALWAYS SWITCH THE ENGINE OFF, wait for all moving parts to stop and allow the
machine to cool down. Prevent the engine from being started accidentally (disconnect the power unit
from the mains). Always bleed pressure from the air hose and tank before attempting maintenance,
attaching tools or accessories.
Unplug the tool from the supply mains. Never plug and switch off the tool during maintenance.
•
Always make sure that all nuts and bolts are firmly tightened and make sure the machine is in good
working order.
•
Keep the machine in good condition, if necessary change warning and instruction labels on the
machine.
•
Always ensure that the ventilation openings are kept clear of debris.
•
For safety reasons, replace worn or damaged parts. Only use original spare parts and accessories. Parts
not tested and approved by the equipment manufacturer can cause unforeseeable damage.
•
Repair and maintenance work other than described in this section, which are more complicated, or it
needs special tools, let it on our authorized service.
DRAINAGE OF AIR-TANK
It is necessary to drain the condensate from the tank after the each use. Periodically (or after completing
work if for more than an hour), drain the condensate that forms inside the reservoir due to the humidity
in the air in order to protect the reservoir from rust and so as not to restrict its capacity.
1.
Drainage has to be done under the pressure,
max. 1 -2 bar.
2.
Tilt the tank to the position of the drainage
output to the lowest part of the tank
(fig. 7).
3.
Remove the screw carefully; the air pressure
will displace the condensate from the tank.
4.
When the tank contains only the clean air,
close and tight the screw.