The concentration of processed gases that can displace breathing air shall be kept within acceptable levels. The user 

shall see the norm EN 12021 for acceptable levels of contaminants in breathing air. 

Separators, traps and draining facilities are required to process liquids produced by the compressor before putting the 

compressor unit into use as these are not supplied; 

 

9.

 

Unpacking

 

 

Carefully check all parts after unpacking the product from the box. 

 

Do not throw away packaging materials until you have not reviewed carefully if they did not 
remain a part of the product. 

 

Parts  of  the  packaging  (plastic  bags,  paper  clips,  etc.)  do  not  leave  within  reach  of  children, 
could be a possible source of danger. There is a danger of swallowing or suffocating! 

 

If you notice transport damage or while unpacking, notify your supplier immediately. Do not 
operate the product! 

 

We recommend save the package for future use. The packaging materials must still be recycled 
or disposed of in compliance with the relevant legislation. Sort different parts of the packaging 
according  to  material  and hand  it to  the  appropriate  collection  sites.  For further information 
contact your local administration. 

Fasteners can become loose during transport in the packaging. 

PACKAGE CONTENTS 

 

1x compressor body, 2x wheel with assembly kit (for 24L, 50L), 2x feet with assembly kit, 1x air filter, 1x 

manual for use 

 

Standard accessories are subject to change without notice. 

This product requires assembly. The product must be assembled correctly before use 

After unpacking the box check the status of the compressor for signs of damage. In particular, carefully 
check the air nozzle. 
Place the compressor on a horizontal, flat and firm surface so that the compressor body is directed 
upward. 
Install transport wheels (if not already installed) to the holders of the wheels on the bottom of the air 
nozzle using screws enclosed 

(fig. 2).

 

Install support foot (if not already installed) to the holder on the bottom of the air nozzle using screw 
enclosed 

(fig. 3).

 

Put the air filter on the thread and tighten it clockwise with your hand 

(fig. 4).

 

Check the tightening of the air tank drain valve 

(fig. 7).

 

Locate the compressor in a clean, dry and well-ventilated area. The compressor should be located 12 to 18 
inches from a wall or any other obstruction that would interfere with the air flow through the fan. Place 
the compressor on a firm level surface. The compressor is designed with heat dissipation fins that allow for 
proper cooling. Keep the fins and other parts that collect dust or dirt clean. A clean compressor runs cooler 
and provides longer service. Do not place rags, containers, or other material on top of the compressor. 
Set the maximum pressure and connect compressor to the power supply. After reaching the maximum 
pressure, properly working compressor off and then check by listening for leaks of compressed air. If you 

Содержание FC6LS

Страница 1: ...al Instruction manual Oil free compressor Feider France ZI 32 rue Aristide Berg s 31270 Cugnaux France MADE IN RPC 2018 Warning Please read the manual carefully before using this machine FC6LS FC24LS...

Страница 2: ...Risk of electric shock Do not open the valve before connecting the air hose Do not use the machine with open or removed covers Do not move it during operation Danger automatic control Attention Hot s...

Страница 3: ...ction hole G main switch O supporting foot H self propelled handle P pressure relief valve Inspection hole is used for inspection and cleaning of the pressure tank may only be performed by an authoriz...

Страница 4: ...50LS is the basic model 2 other models were designed to same structure with FC50LS except rated power and the volume of tank 3 the assessment of each type of model covers each series of machine of ess...

Страница 5: ......

Страница 6: ...PECIFIC TERMS AND CONDITIONS OF USE This product is exclusively intended for the use for generating compressed air for tools operated by compressed air your new air compressor can be used for operatin...

Страница 7: ...s product Carefully read the instruction manual Learn how to use this product all restrictions and what risks could related with its use Learn the product quickly stop and turn off the controls Be car...

Страница 8: ...ozzle leaks showing signs of deep corrosion mechanical damage or escape the air immediately turn off the machine and entrust it to an authorized service center Usingthemachinewith adamaged airnozzlema...

Страница 9: ...the product Dangers caused by unexpected starting unexpected exceeding of engine revs caused by defect failure of control system relate to the defects by the handle and placing of drivers Dangers cau...

Страница 10: ...bly kit 1x air filter 1x manual for use Standard accessories are subject to change without notice This product requires assembly The product must be assembled correctly before use After unpacking the...

Страница 11: ...o manometer fig 5A 2 Push the air hose connector into the socket fig 5B and release the collar 3 Check if the air hose is connected properly DISCONNECTING OF THE AIR HOSE 1 Push the air hose connector...

Страница 12: ...AYS SWITCH THE ENGINE OFF wait for all moving parts to stop and allow the machine to cool down Prevent the engine from being started accidentally disconnect the power unit from the mains Always bleed...

Страница 13: ...an the machine after each use Do not let the handles contaminate with oil or grease Clean the handle clean with a damp cloth washed in soapy water Never use aggressive detergents or solvents for clean...

Страница 14: ...hether you need technical advice repairs or genuine factory replacement parts contact SWAP Information on service locations visit WWW SWAP EUROPE COM When ordering spare parts please quote the part nu...

Страница 15: ...Serial number FC6LS FC24LS FC50LS Complies with the provisions of the Directive Machinery 2006 42 EC and national laws transposing it Also complies with the following European directives EMC Directiv...

Отзывы: