background image

mr

.

steam

®

 

Electric Towel Warmers

   

Installation and Operating Instructions

________________________________________________________________

 

Sliding Escutcheon

     Set Screw

Towel Warmer

Header

Finished surface of wall

Brass Insert

     Screw

MODELS  W542 & W634 

Box Contents

• Towel Warmer 

• (3) Small Screws 

• (4) Bracket Escutcheons  • (1) Wire Box Escutcheon
• (4) Large Screw 

• (4) Bracket Set Screws 

• (1) Wiring Box Set Screw  • (4) Brass Inserts
• (1) Wire Box Flange 

• (1) Allen Key

• Warranty 

• Instruction & Operation 

 

   Manual 

1. Remove Towel Warmer and parts from the packing materials.
2. Rotate the two upper and two lower brackets into position as 

shown.

IMPORTANT: 

DO NOT LOOSEN SCREWS TO SWIVEL

BRACKETS. LOOSENING SCREWS WILL CAUSE INTERNAL

LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE.

3. Using the allen key provided, loosen the wiring 

box set screw. DO NOT remove the wiring box.

4. Rotate the wiring box as shown. Tighten the set screw 

firmly to prevent the wiring box from rotating.

NOTE:

 The wiring box and brackets on model W542 can be 

rotated in either direction to result in a right or left handed 

wiring box.

5. Measure the towel warmer and mark the location where  

the brass inserts will be mounted to hang the towel warmer.  

Before securing the towel warmer to the wall check to  

ensure the mounting points are level.

6. Using the screws provided secure the brass inserts to the 

wall.

7. Gently slide the towel warmer onto the brass inserts as 

shown and mark the location for the wiring flange.

8. Remove the towel warmer and secure the flange to the wall 

per the instructions on page 7.

9. Before securing the towel warmer to the wall put an  

escutcheon on each of the 4 brackets. The open end of  

the escutcheon should face the wall as shown.

10. Secure the towel warmer to the brass inserts using the set 

screws provided.  When the towel  warmer is secured to the 

wall slide the escutcheons against the wall to hide the  

mounting point.

 

If a single gang electric box has been 

roughed in See page 3 for instructions.

 

Install Towel Warmers in upright position 

only. Locate with indicator light on bottom as shown. Failure to 

install properly may result in a hazardous condition.

Brass Insert

Upper

Brackets

Bracket

Escutcheons

Wiring Box 

Flange

Wiring Box

Escutcheon

Lower 

Brackets

Level

Wiring

Box

IMPORTANT:

 DO NOT LOOSEN SCREWS 

ON TOP OR BOTTOM BRACKETS. LOOSENING 

SCREWS WILL CAUSE INTERNAL LIQUID TO 

ESCAPE AND CAUSE PRODUCT DAMAGE.

5

!

WARNING

!

WARNING

Содержание mr steam Fifth Avenue W500

Страница 1: ...Fifth Avenue Collection Electric Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc pur 103852 rev 1 15 IMPORTANT NOTE As you follow these instructions you will notice warning an...

Страница 2: ...n precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDIN...

Страница 3: ...formation DO NOT install the Towel Warmer without these instructions Cover Plate Part Numbers Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 10387...

Страница 4: ...C D W 500 22 5 8 W 542 1 1 8 2 3 4 18 1 2 243 4 W 634 1 1 8 2 3 4 143 16 2611 16 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install prope...

Страница 5: ...rk the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided...

Страница 6: ...n on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to...

Страница 7: ...tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY...

Страница 8: ...upply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of pur 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes...

Страница 9: ...s properly attached to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS 3 Do not use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their...

Страница 10: ...Minimum Header Size 2 x 6 18 5 Inlet Outlet Pipe Center to Center 22 Min Header Length Sliding Escutcheon Set Screw Towel Warmer Header Finished surface of wall Brass Insert Screw STEP 1 PRE INSTALLAT...

Страница 11: ...Straight coupling or similar Field Plumbing Escutcheon Washer Valve Union STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facili...

Страница 12: ...Turn this union only to assemble the valve to the upright tube 1 2 Pipe field supplied Valve Washer Optional eccentric coupling supplied Do not spin this valve onto the upright tube as this may cause...