Install Towel Warmers in upright position only. Locate 

with indicator light on bottom as shown. Failure to 

install properly may result in overheating and a haz-

ardous condition.

IMPORTANT NOTE:

 Towel Warmers may have 

small dimensional variations and must be measured 

prior to installation.

This 

End

Up

This 

End

Up

MOUNTING

!

WARNING

Содержание mr steam Fifth Avenue W500

Страница 1: ...Fifth Avenue Collection Electric Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc pur 103852 rev 1 15 IMPORTANT NOTE As you follow these instructions you will notice warning an...

Страница 2: ...n precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDIN...

Страница 3: ...formation DO NOT install the Towel Warmer without these instructions Cover Plate Part Numbers Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 10387...

Страница 4: ...C D W 500 22 5 8 W 542 1 1 8 2 3 4 18 1 2 243 4 W 634 1 1 8 2 3 4 143 16 2611 16 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install prope...

Страница 5: ...rk the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided...

Страница 6: ...n on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to...

Страница 7: ...tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY...

Страница 8: ...upply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of pur 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes...

Страница 9: ...s properly attached to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS 3 Do not use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their...

Страница 10: ...Minimum Header Size 2 x 6 18 5 Inlet Outlet Pipe Center to Center 22 Min Header Length Sliding Escutcheon Set Screw Towel Warmer Header Finished surface of wall Brass Insert Screw STEP 1 PRE INSTALLAT...

Страница 11: ...Straight coupling or similar Field Plumbing Escutcheon Washer Valve Union STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facili...

Страница 12: ...Turn this union only to assemble the valve to the upright tube 1 2 Pipe field supplied Valve Washer Optional eccentric coupling supplied Do not spin this valve onto the upright tube as this may cause...

Отзывы: