mr
.
steam
®
C L U B T H E R A P Y
Installation, Operating & Maintenance Manual
_________________________________________________________________________________________
3
If acrylic, fiberglass or other non-heat resistant materials are
used as part of the steam room enclosure. Consult with the material manu-
facture and see pg. 7, “Installing the AromaSteam Steamhead" for addition-
al details.
IMPORTANT NOTES:
This document contains important safety, operation and maintenance infor-
mation. Leave this document with the club/spa management.
Do not discard this document.
The following general information should be used in conjunction with con-
sultations with an architect, designer and contractor in determining factors
necessary in providing a suitable and safe steam room.
MrSteam CT steam generators are intended to be operated with MrSteam’s
iTempo/Plus
™
, iSteam
®
and CT SteamStop
®
only, and are to be installed
strictly in accordance with the specific instructions contained in this manual
and as supplied in the manuals provided with the controls or accessories.
Never use damaged equipment, doing so may
result in an inoperative or hazardous installation.
Discontinue use of the steam generator and control if the steam
generator or control are damaged or otherwise not functioning
properly. Doing so may result in an inoperative or hazardous
installation
ELECTRICAL SHOCK HAZARD. MrSteam steam generators are
connected to 208V or 240V line voltage and contain live electri-
cal components. All installation and service to be performed by
qualified and licensed electricians and plumbers only. nstallation
or service by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous condition.
Do Not alter or modify any MrSteam product.
Doing so may result in an inoperable or hazardous
installation and will void the warranty
8. Steam room tile construction information is available from the Tile
Council of America, Inc. by purchasing
the TCA Handbook for Ceramic Tile Installation.at (864) 646-8453
or www.tileusa.com.
9. Windows that are part of the steam room should be double
paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding 8 feet may
require a higher-rated steam generator.
The warning
placard is located in the docu-
mentation envelope. This plac-
ard is an essential part of provid-
ing a safe environment for steam
room users. This placard must be
mounted to the wall of the
shower or steam enclosure, at a
point visible to all users. Failure
to mount this placard may result
in serious injury or death. For a
replacement placard contact
MrSteam customer service at 1-
800-76-STEAM or
[email protected]
Before Installing
Carefully inspect the CT steam generator and packaging for
shipping damage. In the event of shipping damage, please
contact the carrier for claim information. Our customer service
department can assist you with any missing or damaged parts.
Read these instructions before installation or service. Although
this CT steam generator has been fully qualified
for shipment by MrSteam, the following must be reviewed for
proper, safe and enjoyable steam bathing:
1. Verify that the model and accessories specifications are cor-
rect for the incoming line voltage.
2. Insure steambath generator has been correctly sized for the
steambath room. Pay particular attention to room volume
Steam Room Guidelines
IMPORTANT NOTE:
Owners/Operators should obtain a
copy and familiarize themselves with the latest edition of the
American College Sports Medicine Health/Fitness Facility
Standards and Guidelines, or a similar resource and reference
publication, and refer to those guidelines for the proper and
safe operation of a spa facility including steam rooms.
1. Steam room must be completely enclosed, with full
walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for
steam containment.
3. If tile-type or other smooth surfaced flooring is used
provide suitable anti-skid strips or equivalent, to
prevent a slipping hazard.
4. Check the suitability of any materials with the
manufacturer. Walls and ceilings must be constructed
of water-resistant, non-corrosive surface, such as tile,
marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of
condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices
should be installed inside the steam room.
and construction. If any questions, please refer to MrSteam sizing
and selection guide on page 2.
3. Marble or glass walls or ceilings “enlarge” the room’s size requir-
ing a generator larger than one based only on the room’s cubic
foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing servicing,
and its distance from the steam room must all be considered
before final installation.
5. Consider any controls and accessories before initiating installa-
tion. Read the Installation & Operation Manual of all controls
and accessories available at
www.mrsteam.com/products/technical-downloads.html
STEAM ROOM BENEFITS
Steam bathing is a communal activity. Enjoy steam together with friends. Relax, knowing
that steam may be a natural detox. Here are some possible benefits of steam bathing:
- Cleanses, nourishes, and hydrates skin
- Boosts metabolism
- Provides relief for respiratory ailments such as colds, flu, allergies, and asthma
- Reduces stress and promotes restful sleep
Follow your steambath with a refreshing shower.
If you would like your own personal steam bath at home contact us at mrsteam.com
REDUCE THE RISK OF OVERHEATING AND SCALDING
1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in a
heated area is capable of causing overheating.
2. Children under the age of 16 should not use the steam bath.
3. Check with a doctor before use if pregnant, diabetic, in poor health or
under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs or
medication is capable of causing unconsciousness.
5. Do not contact steam head or steam at the steam head.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
Use care when entering or exiting the steam room, floor may be slippery.
Note:
For additional safety considerations see owner's manual.
MrSteam 43-20 34th Street, Long island City NY 11101 1-800-76-STEAM www.mrsteam.com
Not Actual Size