Installation, Operating & Maintenance Manual
_________________________________________________________________________________________
Electrical
All electrical wiring to be installed by a qualified licensed elec-
trician in accordance with National Electrical Code and local
electrical code.
Power Wiring-
See “Field Power Wiring” Diagrams (below)
1. Check power voltage. Use 240V rated unit when supply is
greater than 208V. Use 208V rated unit for 208V power.
2. Use minimum 90˚ C/300V rated insulated copper conductors
only, sized in accordance with National Electrical Code and
local electrical code for the current in Ampere Chart. If
allowed by codes, NM cable may require a larger wire size
than as listed on the chart.
3. Connect suitably sized equipment grounding wire to ground
terminal provided.
4. Install a separate circuit breaker between supply and unit.
Provide a power supply disconnect within sight of the steam
generator or one that is capable of being locked in the open
position.
5. For single phase units, use two-wire supply source and equip-
ment grounding wire. Neutral (white) wire is not required.
CHART
___________________________________________________________________________
Model
Max Room
KW
Volts
Wire Size
Wire Size
No.
Vol (Cu. Ft.*)
1 PH
†
Phase Amps (
AWG) for 40˚ C (AWG) for 45˚ C
Ambient
Ambient
___________________________________________________________________________
208
1
29
8
8
CT6E
150
6.0
3
17
10
10
240
1
25
8
8
3
14
12
12
___________________________________________________________________________
208
1
44
8
6
CT9E
360
9.0
3
25
8
8
240
1
38
8
8
3
22
10
10
___________________________________________________________________________
208
1
58
6
4
CT12E
575
12.0
3
34
8
8
240
1
50
6
6
3
29
8
8
___________________________________________________________________________
208
1
73
4
3
CT15E
675
15.0
3
42
8
6
240
1
63
4
4
3
36
8
8
____________________________________________________________
*See page 2 for room sizing.
†
All specifications shown are for 208V and 240V. Consult factory for
other voltage specifications.
Provide a power supply disconnect within sight of the steam
generator or one that is capable of being locked in the open position as permitted by code.
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water Inlet
Thermostat
Liquid
Level Probe
Power Block
Power Supply
Knock-Out
Contactor
Steam Outlet
Fuses
AutoFlush Plug and
Play Connector
(see page 13)
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water Inlet
AutoFlush Plug and
Play Connector
(see page 13)
Thermostat
Liquid
Level Probe
Power Supply
Knock-Out
Contactor
Steam Outlet
Field Power Wiring
1. TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER SUPPLY
DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
Models CT6E – CT9E
(single phase wiring shown)
Models CT12E & 15E
(single phase wiring shown)
FOR ILLUSTRATIVE PURPOSES ONLY
Some components may be omitted
or altered for clarity. Do not use for
wiring, repair or other purposes not
related to component identification.
9