background image

mr

.

steam

®

C L U B T H E R A P Y

Installation, Operating & Maintenance Manual

_________________________________________________________________________________________

13

AutoFlush

®

Box Contents

• AutoFlush Valve with Cord
• Installation instructions.

Operation

The AutoFlush System feature automatically
drains the CT system following each use.
A time delay allows the water to cool down
(about two hours) before it drains by gravity for a
safe and gentle operation.

Unit drains by gravity.

Installation Instructions

1.

Plumbing to be performed by a qualified

plumber and shall be in accordance with
applicable national and local codes. Unit drains
by gravity. A drain line that is lower than the
AutoFlush assembly must be available. The
AutoFlush System valve outlet is 1" NPT. Check
plumbing code for receptor, trap and vent requirements.

2.

Use copper or brass nipple 1" NPT x 3

1

2

" or longer

(not supplied) to connect AutoFlush valve to the Drain Valve,
noting the direction of flow on the valve body.

DO NOT REMOVE THE DRAIN VALVE

Removal may cause equipment and property damage.
If there is not enough room for the valve, an elbow and
a short nipple (not provided) can be added.

3.

Open Drain Valve (handle must be aligned with brass nipple).

4.

Connect the AutoFlush System cord connector to

the three pin connector as shown.

Do not drain into a steam enclosure or any

location where accidental contact with drain water may occur.
In the event of a power failure the AutoFlush System valve will
open and may discharge boiling water.

Sweat Fittings

When using sweat fittings use only tin base solder with a melt-
ing point below 600 degrees F. Do not overheat. Ends of water
supply tubing must be thoroughly clean for a minimum distance
of 1" from ends. Do not remove valve cover.

To Check Operation

1. Turn on MrSteam and allow tank to fill with water.
2. Turn off MrSteam control. Water should stay in tank.
3. Turn off power at the panel box. Water should

discharge from tank.

4. Turn on power at panel box.
5. Repeat

Drain Valve

DO NOT TURN OR REMOVE

THE DRAIN VALVE

(shown in the correct open position)

Steam Generator

Nipple

Plumb to
Drain Line

AutoFlush Valve

AutoFlush Cord

AutoFlush Valve

3 Pin Connector
for AutoFlush

AutoFlush Cord Connector

Drain Valve

(shown in the correct open position)

DO NOT REMOVE THIS DRAIN VALVE

Steam Generator

Nipple
copper or brass
nipple 1" NPT x
3

1

2

"or longer

(not supplied)

Plumb to
Drain Line

Arrow indicates correct
direction of flow

PROVIDE DRAIN PLUMBING ACCORDING
TO LOCAL CODES. PLUMB AS REQUIRED
FOR AUTOFLUSH SYSTEM

.

Содержание mr. steam Club Therapy CT6E

Страница 1: ...mr steam Feel Good Inc Club Therapy Steambath Generator Systems Installation Operation Maintenance Manual Models CT6E CT9E CT12E CT15E Installation Operation Maintenance Manual...

Страница 2: ...ical Specifications Field Power Wiring 9 Wiring Diagrams 10 Initial Start Up Checkout Maintenance Generator Operations and Troubleshooting 11 System Status Codes Liquid Level Control Board 12 AutoFlus...

Страница 3: ...blood pressure and circulation A warning placard has been provided in the Information envelope This placard is an essential part of providing a safe environment for steam room users This placard must...

Страница 4: ...to be installed inside the steam room when the control is mounted outside the steam room Steam Generators Specification Chart Amps for Total Adj Wire Water Usage Shipping Model No KW 240v 1PH Room Vo...

Страница 5: ...r shipment by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are cor rect for the incoming line voltage 2 Ins...

Страница 6: ...rovide supports under steam generator when wall mounting Keyhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots 6 Instal...

Страница 7: ...formation Remote Sensor see page 16 CT SteamStop Control See page 17 for installation information iTempo Plus or iSteam Control See page 16 Field installed water supply line IMPORTANT Locate the remot...

Страница 8: ...on Manual for installation information before the steam piping is installed at www mrsteam com technical downloads Steam Piping 1 2 NPT 1 Do not install any valve in steam piping Flow of steam must be...

Страница 9: ...is finished STEP 4 After the wall has been finished mark on the nipple where the surface of the wall is Remove the nipple and measure the por tion that was in the wall the end to your mark Subtract 1...

Страница 10: ...inches MM Water Inlet Steam Outlet Safety Valve AutoFlush Manual Drain Valve Generator Dimensions IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as requi...

Страница 11: ..._ 208 1 29 8 8 CT6E 150 6 0 3 17 10 10 240 1 25 8 8 3 14 12 12 ___________________________________________________________________________ 208 1 44 8 6 CT9E 360 9 0 3 25 8 8 240 1 38 8 8 3 22 10 10 __...

Страница 12: ...T GRAY WHT BLUE RED WHT RED Remove Jumper when CU HTC is installed CONTROL BOARD CONTACTOR Heating Element To Probe AutoFlush CT SteamStop iTempo Plus or iSteam Control TRANSFORMER POWER INPUT L1 L2 F...

Страница 13: ...from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again 5 Ref...

Страница 14: ...rol Board EXPLANATION OF LED INDICATORS _____________________________________________________________________________________________________________________________________________ GREEN LED is ON wh...

Страница 15: ...Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or any location where ac...

Страница 16: ...oses not related to component identification Replacement Parts List ____________________________________________________________ Part No Description Product ___________________________________________...

Страница 17: ...r or other purposes not related to component identification 15 Transformer Drain Line Liquid Level Control Board Fuses Water Inlet Water Feed Solenoid Safety Valve AutoFlush Valve Stainless Steel Tank...

Страница 18: ...le length is 30 feet Insure that the control and or steam generator are located according ly An optional 60 foot cable is available PN 103990 60 for iTempo and PN 104117 60 for iSteam Contact a MrStea...

Страница 19: ...sket The connector is keyed and will only connect in one orientation with the tab facing up LED indicator will light up when the generator is ON Using the CT SteamStop Control The CT SteamStop control...

Страница 20: ...meWizard iButler iGenie iSizing iSteam iTempo iTempo Plus Making Wellness a Way of Life Music Therapy Spa Package Steam Genie Steam on Demand Steam Home SmartSizing SteamStart SteamStop SteamTherapy S...

Отзывы: