13
AutoFlush
®
Box Contents
• AutoFlush Valve with Cord
• Installation instructions.
Operation
The AutoFlush System feature automatically
drains the CT system following each use.
A time delay allows the water to cool down
(about two hours) before it drains by gravity for a
safe and gentle operation.
Unit drains by gravity.
Installation Instructions
1.
Plumbing to be performed by a qualified
plumber and shall be in accordance with
applicable national and local codes. Unit drains
by gravity. A drain line that is lower than the
AutoFlush assembly must be available. The
AutoFlush System valve outlet is 1" NPT. Check
plumbing code for receptor, trap and vent requirements.
2.
Use copper or brass nipple 1" NPT x 3
1
⁄
2
" or longer
(not supplied) to connect AutoFlush valve to the Drain Valve,
noting the direction of flow on the valve body.
DO NOT REMOVE THE DRAIN VALVE
Removal may cause equipment and property damage.
If there is not enough room for the valve, an elbow and
a short nipple (not provided) can be added.
3.
Open Drain Valve (handle must be aligned with brass nipple).
4.
Connect the AutoFlush System cord connector to
the three pin connector as shown.
Do not drain into a steam enclosure or any
location where accidental contact with drain water may occur.
In the event of a power failure the AutoFlush System valve will
open and may discharge boiling water.
Sweat Fittings
When using sweat fittings use only tin base solder with a melt-
ing point below 600 degrees F. Do not overheat. Ends of water
supply tubing must be thoroughly clean for a minimum distance
of 1" from ends. Do not remove valve cover.
To Check Operation
1. Turn on MrSteam and allow tank to fill with water.
2. Turn off MrSteam control. Water should stay in tank.
3. Turn off power at the panel box. Water should
discharge from tank.
4. Turn on power at panel box.
5. Repeat
Drain Valve
DO NOT TURN OR REMOVE
THE DRAIN VALVE
(shown in the correct open position)
Steam Generator
Nipple
Plumb to
Drain Line
AutoFlush Valve
AutoFlush Cord
AutoFlush Valve
3 Pin Connector
for AutoFlush
AutoFlush Cord Connector
Drain Valve
(shown in the correct open position)
DO NOT REMOVE THIS DRAIN VALVE
Steam Generator
Nipple
copper or brass
nipple 1" NPT x
3
1
⁄
2
"or longer
(not supplied)
Plumb to
Drain Line
Arrow indicates correct
direction of flow
PROVIDE DRAIN PLUMBING ACCORDING
TO LOCAL CODES. PLUMB AS REQUIRED
FOR AUTOFLUSH SYSTEM
.