Page 25 of 39
(13)
PERIODIC MAINTENANCE (CLEAN CONDENSER)
Cleaning Condenser Coil (All Self Contained Refrigerated Models)
NOTICE:
Condenser coil must be cleaned a minimum of twice per month to insure
proper refrigeration performance and prevent compressor failure. In some
environments, it may be necessary to clean more frequently. FAILURE TO
CLEAN CONDENSER COIL WILL VOID COMPRESSOR WARRANTY.
It is very important that the condenser coil is cleaned twice per month to ensure proper refrigeration performance and to
prevent compressor failure. Failure to clean condenser coil will void condenser warranty.
1.
Disconnect power to the unit
2.
Remove the rear base panel located on the back of the unit by removing the rear panel retaining screws.
3.
Carefully vacuum the front surface of condenser coil. Take care not to bend coil fins with vacuum cleaner nozzle.
A brush attachment works well to prevent this.
4.
Reinstall rear panel and retaining screws.
SIX REAR PANEL SCREWS
REAR BASE PANEL
VACUUM FRONT SURFACE
OF CONDENSER COIL
Figure 2 - Condenser Cleaning