Page 6 of 39
(3)
PRE-INSTALLATION PROCEDURES
3.1
INSPECTION FOR SHIPPING DAMAGE
You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as
soon as they arrive. If damage is noted to shipping crates, cartons, or if a shortage is found, note this on the bill of lading
(all copies) prior to signing.
If damage is discovered when the case is uncrated, immediately call the delivering truck line and follow up the call with a
written report indicating concealed damage to your shipment. Ask for an immediate inspection of your concealed damage
item. Crating material must be retained to show the inspector from the truck line.
(4)
GENERAL ELECTRICAL & GROUNDING
DANGER:
Improper or faulty hookup of electrical components in the display case can result in
severe injury or death.
4.1
CORD CONNECTED
All standard models are supplied with a power cord that is properly sized to the amperage requirements of the
case. See the electrical data plate located on the rear left interior of the case for the proper circuit size for each
case.
The cord is factory installed protruding from the bottom rear corner of the case.
A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
4.2
PERMANENT CONNECTED (OPTION)
Only a licensed electrician must perform all case electrical connections.
All electrical wiring hookups must be done in accordance with all applicable local, regional, or national electrical
standards.
A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
The electrical service must be grounded upon installation.
See the electrical data plate located at the rear of the case for proper circuit size and wire ampacity.
The electrical connection box is accessible from the rear of the case with rear grill removed.
FIELD CONNECTION BOX
FLOOR CONDUIT
CONNECTION 0.875 DIAMETER
CONDUIT OR POWER CORD
CONNECTION 0.875 DIAMETER
REAR BASE PANEL
SIX REAR PANEL SCREWS