out condensate drain hose. Note Drain hose can be run in vertical direction but must not exceed height of
15 feet
Note: There is a piece of cardboard that has to be removed from the side of the pump to free up the
float. If this is not done, the pump will not turn on and the pan will overflow.
Electronic Expansion Valve (EEV) After 1/20
A traditional TXV uses springs and a temperature bulb to open and close a valve port that controls the flow
of refrigerant entering the evaporator coil. An electronic expansion valve (EEV) controls the refrigerant
flow much more precisely, increasing the performance and efficiency of the refrigeration system. The EEV
controls the flow of Refrigerant by opening and closing the valve port based on the response to signals sent
to the EEV by an electronic controller. The electronic Control bases these signals by processing
information provided from a temperature sensor and pressure transducer located on the discharge side of
the evaporator coil.
These sensors monitor the evaporator superheat and protects the compressor from any liquid flood back
under low superheat conditions.
EEV Controller Settings
The
electronic expansion valve controller also allows the use of different types of refrigerants without the
need to change the expansion valve.
The controller is set from the factory to run on 449A refrigerant and will not need any changes to the
control unless another refrigerant is used.
Note: Check your State and Local regulations for approved refrigerants for your install location.
Federal Industries is not liable for any alternate refrigerants used.
The control is located in the rear center of the base.
Note: Never change any of the other setting other than the refrigerant type. It may also be necessary
to change the superheat setting only when using a different refrigerant
.
Содержание ITD Series
Страница 14: ...14 Counter ITR60 Self Contained Counter ITRSS60 Self Contained...
Страница 15: ...15 Floor ITR ITRSS 36 Self Contained...
Страница 16: ...16 Floor ITR ITRSS 48 Self Contained Floor ITR60 Self Contained...
Страница 17: ...17 Floor ITRSS60 Self Contained Refrigerated Remote Models...
Страница 18: ...18 All ITR Counter Remote All ITR Floor Remote All ITRSS Counter Remote...
Страница 19: ...19 All ITRSS Floor Remote Floor ITD ITDSS NON Refrigerated...
Страница 60: ...60 ITRSS6026 ITRSS6034 Refrigerated Self Contained After 12 1 19 All Refrigerated Remote Before 12 1 19...
Страница 61: ...61 All Refrigerated Remote After 12 1 19...