![Federal Signal Corporation IMPAXX Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/federal-signal-corporation/impaxx-series/impaxx-series_installation-and-maintenance-manual_3814775016.webp)
Wiring the IMPAXX in the Vehicle
16
IMPAXX
®
LED Light Heads
Federal Signal
www.fedsig.com
2.
To reverse the direction of pattern selection, hold the green
wire to negative ground power (-GND) for slightly longer than
1 second, but less than 3 seconds.
3.
When finished, cut and seal the green wire.
Table 1 Flash patterns for IMPAXX Series LED Light Heads
Flash
Pattern Description
Flash
Pattern Description
1
Null (off)
14
75 FPM Double
2
79 FPM Power Quad*
15
150 FPM Triple
3
150 FPM Single
16
75 FPM Triple
4
151 FPM Single
17
5 Single
at
680 FPM
4 Single
at
216 FPM
5
74 FPM Single*
18
4 Single
at
570 FPM
3 Single
at
246 FPM
6
75 FPM Single
19
3 Single
at
460 FPM
2 Quad
at
75 FPM
7
240 FPM Single
20
Progressive (flashes
start slow and increase
in speed)
8
241 FPM Single
21
4 Single
at
154 FPM
2 Quad
at
75 FPM
9
240 FPM Double*
22
Random
10
241 FPM Double
23
3 quick flashes, then
stays in Steady Burn
11
150 FPM Double
24
FedPulse 75
12
151 FPM Double
25
Steady Burn
13
74 FPM Double
*Conforms to CCR Title 13
NOTE:
Single, Double, and Quad refer to the number of flashing
intervals.