Federal Signal Corporation 2001-AC Скачать руководство пользователя страница 7

2001-AC 

Safety Message 

   

 

Safety Message 

 

It is important to follow all instructions shipped with this product. This 
device is to be installed by trained personnel who are thoroughly 
familiar with the country electric codes and will follow these guidelines 
as well as local codes.  

Listed below are important safety instructions and precautions you should follow: 

Important Notice 

Federal Signal reserves the right to make changes to devices and specifications 
detailed in the manual at any time in order to improve reliability, function, or design. 
The information in this manual has been carefully checked and is believed to be 
accurate; however, no responsibility is assumed for any inaccuracies. 

Publications 

Federal Signal recommends the following publications from the Federal Emergency 
Management Agency for assistance with planning an outdoor warning system:  

 

The “Outdoor Warning Guide” (CPG 1-17) 

 

“Civil Preparedness, Principles of Warning” (CPG 1-14)  

 

FEMA-REP-1, Appendix 3 (Nuclear Plant Guideline) 

 

FEMA-REP-10 (Nuclear Plant Guideline). 

Planning 

 

If suitable warning equipment is not selected, the installation site for the siren is 
not selected properly or the siren is not installed properly, it may not produce the 
intended optimum audible warning. Follow Federal Emergency Management 
Agency (FEMA) recommendations. 

 

If sirens are not activated in a timely manner when an emergency condition 
exists, they cannot provide the intended audible warning. It is imperative that 
knowledgeable people, who are provided with the necessary information, are 
available at all times to authorize the activation of the sirens. 

 

When sirens are used out of doors, people indoors may not be able to hear the 
warning signals. Separate warning devices or procedures may be needed to 
effectively warn people indoors. 

Содержание 2001-AC

Страница 1: ...2001 AC DC Motor Starters and Transformer Rectifier Plus Options 2001HR Holding Relay Radio Activation Installation and Operation Manual 255252 Rev L4 0616 Printed in U S A...

Страница 2: ...2001 AC Copyright 2016 Federal Signal Corporation...

Страница 3: ...to the product or labor charges for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the...

Страница 4: ...2001 AC Website http www alertnotification net...

Страница 5: ...01HR 5 Battery Backup 5 Specifications 6 Installation Instructions 7 Location and Installation 7 Locating the 2001 AC 7 Installation Requirements 9 Installation 9 Pole Mounting 9 Flat Surface Mount 10...

Страница 6: ...gure 3 Typical Siren Installation Drawing 8 Figure 4 Motor Starter Enclosure Parts List 11 Figure 5 Motor Starter Wiring Diagram with HR Option 12 Figure 6 Typical Wiring Diagram 13 Figure 7 Terminal...

Страница 7: ...agement Agency for assistance with planning an outdoor warning system The Outdoor Warning Guide CPG 1 17 Civil Preparedness Principles of Warning CPG 1 14 FEMA REP 1 Appendix 3 Nuclear Plant Guideline...

Страница 8: ...rocution or severe personal injury can occur when performing various installation and service functions such as making electrical connections drilling holes or lifting equipment Therefore only experie...

Страница 9: ...ead and thoroughly understand all safety notices in this manual and all operations related items in all instruction manuals shipped with equipment Thoroughly discuss all contingency plans with those r...

Страница 10: ...as a siren Figure 1 2001 AC FC control purchased separately Describing the Motor Starter and the Transformer Rectifier The 2001 AC consists of two enclosures that you can separately mount for ease of...

Страница 11: ...FC Controllers are capable of both radio and local push button control These controllers are available in UHF and VHF bands Landline cellular satellite and IP options are available contact your local...

Страница 12: ...5 VAC at 10 Amps Operating Current 100 Amps Nom Fusing 200 Amps fast Contactors Contact Rating 200 A at 48 VDC Coil 48 VDC 110 ohms General Continuous Full Output Signaling Time 30 minutes Operating T...

Страница 13: ...eral Signal recommends that you install the 2001 AC within 50 feet of the siren or other equipment being activated If it is necessary to make a longer cable run Federal Signal recommends increasing th...

Страница 14: ...8 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 3 Typical Siren Installation Drawing...

Страница 15: ...rminals 1 2 AWG inch ring terminal 1 12 AWG inch ring terminal 3 10 AWG wire nuts Approximately 50 feet of 1 inch conduit inch conduit length depends on install Ground wiring rod and or clamps Install...

Страница 16: ...accordance with local and national electric codes on the pole beneath or opposite the Control Unit Transformer Rectifier assembly in line with the primary AC service Flat Surface Mount To attach the...

Страница 17: ...2001 AC 11 Installation Instructions Figure 4 Motor Starter Enclosure Parts List...

Страница 18: ...12 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 5 Motor Starter Wiring Diagram with HR Option...

Страница 19: ...2001 AC 13 Installation Instructions Figure 6 Typical Wiring Diagram...

Страница 20: ...Motor Starter Wiring and Figure 6 Typical Wiring Diagram Typical connections between the siren and control unit are accomplished using user supplied wires Two 2 AWG wires provide operating power to th...

Страница 21: ...al Block in Rotator Housing 5 Connect a 2 AWG wire 48 VDC from the terminal block in the rotator housing terminal 2 to the rotor control relay K2 2 user supplied inch ring terminal required 6 Connect...

Страница 22: ...Transformer Rectifier Enclosure and the Motor Starter Enclosure 5 Route two user supplied wires through the conduit that was just installed between the Transformer Rectifier and Motor Starter Use 3 A...

Страница 23: ...motor and the rotator motor are activated When the connection to ground is removed power to the siren motor is removed and the rotator motor remains on for fifteen 15 seconds to allow a single contac...

Страница 24: ...est the 2001 AC for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public c...

Страница 25: ...could occur when working on this equipment Service should only be performed by personnel familiar with 240 VAC power and only after reading this manual The following checklist should be completed if...

Страница 26: ...20 2001 AC Service and Maintenance MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 9 Transformer...

Страница 27: ...6 I Installation Instructions 7 Installation Requirements 9 Introduction to the 2001 AC 4 L Locating the 2001 AC 7 M Maintenance 18 Motor Starter 4 P Pole Mounting 9 Pre Operation Checkout 17 Preventi...

Страница 28: ...2645 Federal Signal Drive University Park IL 60484 3167 Phone 708 534 3400 Website http www alertnotification net...

Отзывы: