Federal Signal Corporation 2001-AC Скачать руководство пользователя страница 3

Limited Warranty 

The Alerting and Notification Systems Division of 

Federal Signal Corporation (Federal)

 warrants 

each new product to be free from defects in material and workmanship, under normal use and 
service, for a period of two years on parts replacement and factory-performed labor (one year for 
Informer, EAS, and Federal software products) from the date of delivery to the first user-purchaser. 
Federal warrants every 2001, Eclipse and 508 Siren (Top of pole only) to be free from defects in 
material, per our standard warranty, under normal use and service for a period of five years on 
parts replacement. 

During this warranty period, the obligation of Federal is limited to repairing or replacing, as Federal 
may elect, any part or parts of such product which after examination by Federal, are determined to 
be defective in material and/or workmanship. 

Federal will provide warranty for any unit, which is delivered, transported prepaid, to the Federal 
factory or designated authorized warranty service center for examination and such examination 
reveals a defect in material and/or workmanship. 

This warranty does not cover travel expenses, the cost of specialized equipment for gaining access 
to the product, or labor charges for removal and re-installation of the product. The Federal Signal 
Corporation warranty shall not apply to components or accessories that have a separate warranty 
by the original manufacturer, such as, but not limited to batteries. 

Federal will provide on-site warranty service during the first 60-days after the completion of the 
installation, when Federal has provided a turn-key installation including optimization and/or 
commissioning services. 

This warranty does not extend to any unit which has been subjected to abuse, misuse, improper 
installation or which has been inadequately maintained, nor to units which have problems related to 
service or modification at any facility other than the Federal factory or authorized warranty service 
centers. Moreover, Federal shall have no liability with respect to defects arising in Products through 
any cause other than ordinary use (such as, for example, accident, fire, lightning, water damage, or 
other remaining acts of God). 

THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT 
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE.  IN NO EVENT SHALL FEDERAL BE LIABLE FOR ANY LOSS OF 
PROFITS OR ANY INDIRECT OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY SUCH 
DEFECT IN MATERIAL WORKMANSHIP. 

 
 
 
 
 
 
 

 

2645 Federal Signal Drive, University Park, IL 60484-3167 

Phone: 708-534-3400 

Содержание 2001-AC

Страница 1: ...2001 AC DC Motor Starters and Transformer Rectifier Plus Options 2001HR Holding Relay Radio Activation Installation and Operation Manual 255252 Rev L4 0616 Printed in U S A...

Страница 2: ...2001 AC Copyright 2016 Federal Signal Corporation...

Страница 3: ...to the product or labor charges for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the...

Страница 4: ...2001 AC Website http www alertnotification net...

Страница 5: ...01HR 5 Battery Backup 5 Specifications 6 Installation Instructions 7 Location and Installation 7 Locating the 2001 AC 7 Installation Requirements 9 Installation 9 Pole Mounting 9 Flat Surface Mount 10...

Страница 6: ...gure 3 Typical Siren Installation Drawing 8 Figure 4 Motor Starter Enclosure Parts List 11 Figure 5 Motor Starter Wiring Diagram with HR Option 12 Figure 6 Typical Wiring Diagram 13 Figure 7 Terminal...

Страница 7: ...agement Agency for assistance with planning an outdoor warning system The Outdoor Warning Guide CPG 1 17 Civil Preparedness Principles of Warning CPG 1 14 FEMA REP 1 Appendix 3 Nuclear Plant Guideline...

Страница 8: ...rocution or severe personal injury can occur when performing various installation and service functions such as making electrical connections drilling holes or lifting equipment Therefore only experie...

Страница 9: ...ead and thoroughly understand all safety notices in this manual and all operations related items in all instruction manuals shipped with equipment Thoroughly discuss all contingency plans with those r...

Страница 10: ...as a siren Figure 1 2001 AC FC control purchased separately Describing the Motor Starter and the Transformer Rectifier The 2001 AC consists of two enclosures that you can separately mount for ease of...

Страница 11: ...FC Controllers are capable of both radio and local push button control These controllers are available in UHF and VHF bands Landline cellular satellite and IP options are available contact your local...

Страница 12: ...5 VAC at 10 Amps Operating Current 100 Amps Nom Fusing 200 Amps fast Contactors Contact Rating 200 A at 48 VDC Coil 48 VDC 110 ohms General Continuous Full Output Signaling Time 30 minutes Operating T...

Страница 13: ...eral Signal recommends that you install the 2001 AC within 50 feet of the siren or other equipment being activated If it is necessary to make a longer cable run Federal Signal recommends increasing th...

Страница 14: ...8 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 3 Typical Siren Installation Drawing...

Страница 15: ...rminals 1 2 AWG inch ring terminal 1 12 AWG inch ring terminal 3 10 AWG wire nuts Approximately 50 feet of 1 inch conduit inch conduit length depends on install Ground wiring rod and or clamps Install...

Страница 16: ...accordance with local and national electric codes on the pole beneath or opposite the Control Unit Transformer Rectifier assembly in line with the primary AC service Flat Surface Mount To attach the...

Страница 17: ...2001 AC 11 Installation Instructions Figure 4 Motor Starter Enclosure Parts List...

Страница 18: ...12 2001 AC Installation Instructions MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 5 Motor Starter Wiring Diagram with HR Option...

Страница 19: ...2001 AC 13 Installation Instructions Figure 6 Typical Wiring Diagram...

Страница 20: ...Motor Starter Wiring and Figure 6 Typical Wiring Diagram Typical connections between the siren and control unit are accomplished using user supplied wires Two 2 AWG wires provide operating power to th...

Страница 21: ...al Block in Rotator Housing 5 Connect a 2 AWG wire 48 VDC from the terminal block in the rotator housing terminal 2 to the rotor control relay K2 2 user supplied inch ring terminal required 6 Connect...

Страница 22: ...Transformer Rectifier Enclosure and the Motor Starter Enclosure 5 Route two user supplied wires through the conduit that was just installed between the Transformer Rectifier and Motor Starter Use 3 A...

Страница 23: ...motor and the rotator motor are activated When the connection to ground is removed power to the siren motor is removed and the rotator motor remains on for fifteen 15 seconds to allow a single contac...

Страница 24: ...est the 2001 AC for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public c...

Страница 25: ...could occur when working on this equipment Service should only be performed by personnel familiar with 240 VAC power and only after reading this manual The following checklist should be completed if...

Страница 26: ...20 2001 AC Service and Maintenance MERGEFORMAT Configuring the Informer IPFORMAT General Descriptionations Figure 9 Transformer...

Страница 27: ...6 I Installation Instructions 7 Installation Requirements 9 Introduction to the 2001 AC 4 L Locating the 2001 AC 7 M Maintenance 18 Motor Starter 4 P Pole Mounting 9 Pre Operation Checkout 17 Preventi...

Страница 28: ...2645 Federal Signal Drive University Park IL 60484 3167 Phone 708 534 3400 Website http www alertnotification net...

Отзывы: