Federal Pump BGP Series Скачать руководство пользователя страница 2

•••••••••••••• 

INTRODUCTION 

Compatible  with  Federal  Pump’s  OS,  FSS,  SBS, 
TCS,  and  NPC  simplex,  and  duplex  control 
system, these series can support 24/7 automatic 
operation  for  standard  pump  service  in 
residential and commercial buildings. 
 
Available  in free  standing  and quick  disconnect, 
the  product  offering  are  also  conveniently  pre-
packaged  in  systems  that  provide  the  end  user 
with  trouble  and  maintenance  free  operation 
when  designed,  installed,  and  maintained 
properly. 

Sewage  pumps  provide  for  the  lifting  and 
disposal  of  sewage  and  sewage  related  fluids 
from  retaining  basins  or  concrete  pits  and  are 
pumped to city water disposal lines where these 
fluids  cannot  drain  under  gravity  conditions 
alone.  Typically  located  below  grade,  sewage 
pumps  provide  building  owners  the  ability  to 
design  and  locate  restroom  or  other  facilities 
below ground that are serviced by these sewage 
lift stations. 

TYPICAL PRE-PACKAGED DUPLEX 

SEWAGE SYSTEM SHOWN WITH 

FRAME, COVER AND BASIN. 

(VALVING AND NOT INCLUDED) 

DISCHARGE 

VENT 

INLET 

GATE VALVE 

CHECK VALVE 

Drill 1/8” Dia.  Vent hole 
to prevent air lock 

6.00” 

Содержание BGP Series

Страница 1: ...i IMPORTANT READ ALL INSTRUCTIONS IN THIS MANUAL BEFORE OPERATING AND SERVING A PUMP...

Страница 2: ...ntained properly Sewage pumps provide for the lifting and disposal of sewage and sewage related fluids from retaining basins or concrete pits and are pumped to city water disposal lines where these fl...

Страница 3: ...NSURE EMPLOYEES WILL NOT BE EXPOSED TO HEALTH HAZARDS IN HANDLING SAID MATIERAL ALL APPLICABLE LAWS AND REGULATIONS SHALL APPLY IWARNING Installation wiring and junction connections must be in accorda...

Страница 4: ...alled in locations classified as hazardous in accordance with the National Electric Code ANSI NFPA 70 IWARNING The Uniform Plumbing Code UPC states that sewage systems shall have an audio and visual a...

Страница 5: ...or re boxed and stored in a dry location If the pump is to be stored for a long period of time rotate the pump shaft periodically to protect the bearings Units should not be stored where temperatures...

Страница 6: ...lled in a trench ditch or hole with a dirt bottom The legs will into the dirt and the suction will become plugged adequate working space A minimum of 8 diametrical clearance around the tank is recomme...

Страница 7: ...unded DO NOT USE THE POWER CABLE TO LIFE PUMP Do not use an extension cord for 1 Phase pump s Always wire the pump as indicated on the wiring diagram inside the control panel 2 OVERLOAD PROTECTION On...

Страница 8: ...ches SW1 SW2 SW3 and 1 high water alarm switch SW4 mounted to the style 1 pilot device with a duplex control panel The level control and high water alarm float should have adequate clearance so they c...

Страница 9: ...he motor before the pump is put into service The resistance values voltage and current should be recorded 5 PUMP DOWN TEST Be sure pump has been properly wired lowered into the basin or lift station C...

Страница 10: ...e any 2 of 3 power supply leads on the motor end of the starter or VFD to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits and fluid...

Страница 11: ...e 5 COOLING OIL INSPECTION Anytime the pump removed from operation the cooling oil in the motor housing should be checked visually for oil level and contamination To check oil set unit upright remove...

Страница 12: ...d PRESSURE TEST AIR FILL MOTOR Remove pipe plug from housing Apply pipe sealant to pressure gauge assembly and tighten into hold Pressurize housing to 10 PSI Use soap solution around the sealed areas...

Страница 13: ...g with washers and grommet d Pull cord through and disconnect the wires from the terminals on power cord Be sure to note wire connections for reassembly e Disconnect cable leads from motor leads and r...

Страница 14: ...ate the impeller by hand and check for smooth rotation If rotation is not smooth check for alignments in the bearing and scratches on the seal faces 2 Upon completion of reassembly rotate the impeller...

Страница 15: ...15 NOTES...

Страница 16: ...l apply to the equipment supplied hereunder or referred to herein or to its performance all such other warranties including any warranty of merchantability or fitness for any purpose being hereby disc...