![Fayat Bomag BW 900-50 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/fayat/bomag-bw-900-50/bomag-bw-900-50_service-manual_546858095.webp)
Fig. 81: Closed circuit
One talks about a closed hydraulic system, when the hydraulic oil
flows from the consumer (3) directly back to the pump (2).
The closed circuit consists of a high and a low pressure side,
depending on the load direction (take-off moment on the con-
sumer).
The high pressure side is protected by high pressure relief valves
(4), which release oil into the low pressure side. The medium
remains in the circuit.
Only the leakage on pump and motor needs to be replenished.
This is accomplished by a charge pump (1) which permanently
draws a sufficient amount of hydraulic fluid (charge capacity) from
the tank and feeds it through a check valves (5) into the low pres-
sure side of the closed circuit. The excess quantity delivered by the
charge pump flows through a charge pressure relief valve (6) back
into the tank. Charging the low pressure side enables the pump (2)
to work with higher operating data.
Closed circuit
Hydraulic system – Basic principles
BW 900-50
98