![Fayat Bomag BW 900-50 Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/fayat/bomag-bw-900-50/bomag-bw-900-50_service-manual_546858091.webp)
Reference values: 12.6 V = fully charged; 12.3 V = 50% dis-
charged.
1.
Recharge the battery immediately after an open-circuit
voltage of 12.25 V or less is reached. Do not perform quick
charging.
The open-circuit voltage of the battery occurs approx. 10 hours
after the last charging process or one hour after the last discharge.
1.
After each charging process allow the battery to rest for one
hour before taking it into service.
2.
For resting periods of more than one month you should
always disconnect the battery. Do not forget to perform reg-
ular open-circuit voltage measurements.
NOTICE!
Exhausted batteries (batteries with formation of
sulphate on the plates) are not covered under war-
ranty!
1.
Open the engine hood.
2.
Fig. 79 and battery compartment.
3.
Clean battery poles and pole clamps and grease them with
pole grease (Vaseline).
4.
Retighten the pole clamps.
5.
Check the fastening of the battery.
Fig. 79