5.
Read charge and high pressure gauges.
ð
Nominal value
Charge pressure gauge: See technical
data.
High pressure gauge: Both identical pres-
sure (charge pressure).
Evaluation of test
If the nominal value is not reached, check
the steering/charge pump.
6.
Move the travel lever quickly forward and backward, read the
pressure gauges.
ð
Nominal value
See technical data.
Evaluation of test
If the charge pressure drops below the
nominal value during the high pressure
test, check the individual components.
If the specified high pressure is not
reached, check the travel pump.
If the starting pressure is reached to one
travel direction only, check the high pres-
sure relief valves.
5.5.3 Adjusting the neutral positions of the travel pump
Special tools
Hydraulic test case
NOTICE!
Perform measurements at operating temperature
of the hydraulic oil (40 °C).
Hydraulic system – Tests and adjustments