Part No. SCAZ042891 1.3.4
23
E&OE
Operating Instructions Scarab M6
USING THE DUST SUPPRESSION SYSTEM
Filling the water tank
Attach the appropriate coupling and water hose to the filler aperture
(1) situated in the right hand tool locker, and fill until the blue float
reaches the top of the water level sight tube (2)situated on the left
hand side of the machine (use clean water).
Using the low pressure water system
The low pressure water is used on the, side brush(es), suction tube(s),
and widesweep brush. To operate any of these functions the relevant
button(s) on the main panel must be selected when in sweep mode.
A shut-off valve is positioned between the pump and tank and must
be open when the system is in use (3).
The side brush(es) are fitted with shut-off valves (
4
).
It is vital that the water system is drained totally if the air
temperature is expected to fall to 0°c or below.
Draining the system -
Open tank Drain valve (5). Remove water
strainer (6).
The hydraulic driven pump should NEVER be permitted to run
dry.
Due the customers requirements, other water features may be
present but not mentioned in this publication
2
5
1
4
3
6